    §3.2 How to judge the liquid flowing direction................ 16 §3.3 How to change between units systems................16 §3.4 How to select a required flow rate unit................16 §3.5 How to use the totalizer multiplier..................16 §3.6 How to open or shut the totalizers..................16 18005851519 Global Shipping sales@ato.com www.ato.com...
  • Page 3 6. Communication Protocol......................29 §6. 0 General..........................29 §6.1 Interface Pin-out Definition....................29 §6.2 the Protocol........................29 §6.3 Protocol Prefix Usage.......................30 §6.4 Codes for the Keypad....................... 31 7. Warranty and Service........................32 §7.1 Warranty........................... 32 §7.2 Service..........................32 18005851519 Global Shipping sales@ato.com www.ato.com...
  • Page 4 §7.2 Software Upgrade Service....................32 18005851519 Global Shipping sales@ato.com www.ato.com...
  • Page 5: Introduction

    * 4 flow totalizers * Patent balanced lower-voltage multi-pulse * built-in date totalizers ultrasonic igniting * built-in data-logger * Work properly near transverters * 0.5 second totalizing period * 100 Pico-second resolution of time measurement 18005851519 Global Shipping www.ato.com sales@ato.com...
  • Page 6: Principle Of Measurement

    Tdown Tup –Tdown ΔT= §1.4 Parts Identification Converter: 18005851519 Global Shipping sales@ato.com www.ato.com...
  • Page 7 Top wierw Upstream transducer socket Downstream transducer socket HANDHOLD Front wiew FLOWMETER LCD display ESN=200408008H ULTRASONIC FLOWMETER LED charge indicator ON OFF CHARG E MENU Keypad • Bottom wiew Pins for battery recharge RS232C communication interface 18005851519 Global Shipping www.ato.com sales@ato.com...
  • Page 8 Transducers: Standard-HM (50mm-700mm) Standard-HS (20mm-100mm) (Optional Accessaries) Cable 5m x2 Red Terminal Red Terminal Blue Terminal Blue Termina Extended Cable 5m x2(Optional Accessaries) Red Terminal Red Terminal Blue Terminal Blue Terminal 18005851519 Global Shipping sales@ato.com www.ato.com...
  • Page 9: Typical Applications

    Each set of the Meinte flow meter has a unique product identification or ESN written into the software that can only be modified with a special tool by the manufacturer. In case of any hardware 18005851519 Global Shipping www.ato.com sales@ato.com...
  • Page 10: Specifications

    10 hours of operation. Data Logger Built-in data logger can store over 2000 lines of data Manual Totalizer 7-digit press-key-to-go totalizer for calibration Housing Material Case Size 180x145x40mm Handset Weight 514g (1.2 lbs) with batteries 18005851519 Global Shipping sales@ato.com www.ato.com...
  • Page 11: Starting Measurement

    When new pipe parameters have been entered or when the power has been just switched on, the flow meter will enter an adjusting mode to make the signals magnified with proper 18005851519 Global Shipping www.ato.com sales@ato.com...
  • Page 12: Keypad

    Each time of the key pressing will proceed to the lower-numbered menu window. For example, if the current window is on M12, the display ▲/ will go to the number M11 window after pressing the key. 18005851519 Global Shipping www.ato.com sales@ato.com...
  • Page 13: Menu Windows Arrangement

    Other menu windows such as M88 have no functions, or functions were cancelled because they are not applied to this version of the software. 18005851519 Global Shipping sales@ato.com www.ato.com...
  • Page 14: Steps To Configure The Parameters

    ▼/ method, and then press key. (8) Press key to enter M24 window to install the transducers on the pipe, and then ▼/ press ey to go to M01 for the results. 18005851519 Global Shipping sales@ato.com www.ato.com...
  • Page 15: Transducers Mounting Allocation

    10 D L up L d n 10 D L up L d n 12 D L up L dn 20 D L u p L dn 20 D L up L dn 30 D 18005851519 Global Shipping sales@ato.com www.ato.com...
  • Page 16: Transducers Installation

    The actual transducers spacing should be as close as possible to the spacing value. §2.8.2 V-method Installation V-method installation is the moswidely used mode for daily measurement with pipe inner diameters ranging from 20 millimeter to 300 millimeter. It is also called reflective mode or 18005851519 Global Shipping sales@ato.com www.ato.com...
  • Page 17: Z-Method Installation

    W-method is usually used on plastic pipes with a diameter from 10 millimeters to 100 millimeters T O P V I E W O F P I P E S e n s o r s S p a c i n g 18005851519 Global Shipping sales@ato.com www.ato.com...
  • Page 18: N-Method Installation

    Bad sonic coupling for the transducers with the pipe. Try to apply more coupler or clean the surface, etc. Pipes are difficult to be measured. Relocation isrecommended. §2.9.3 Total Transit Time and Delta Time The numbers displayed on menu window M93 are called total transit time and delta time 18005851519 Global Shipping www.ato.com sales@ato.com...
  • Page 19: Time Ratio Between The Measured Total Transit Time And The Calculated Time

    If the transducers are installed properly in the right directions. If the mounting location is good and if the pipe has changed shape or if there is too much fouling inside the pipes Other poor conditions. 18005851519 sales@ato.com Global Shipping www.ato.com...
  • Page 20: How To

    §3.6 How to open or shut the totalizers Use M34, M35 and M36 to turn on or turn off the POS, NEG, or NET totalizer respectively. §3.7 How to reset the totalizers Use M37 to reset the proper totalizer. 18005851519 sales@ato.com Global Shipping www.ato.com...
  • Page 21: How To Restore The Flow Meter With Default Setups

    The system can be locked without a password or with a one 1 to 4 digit password. With a no- password locking, directly press the ENT key when the password input prompt displays. 18005851519 sales@ato.com Global Shipping www.ato.com...
  • Page 22: How To Use The Built-In Data Logger

    The totalizer pulse output can only be realized by mapping the pulse output to the OCT or BUZZER hardware devices. For example, assume that the POS totalizer pulse output is needed, and every pulse should represent 0.1cubic meter of liquid flow; the pulse output will be mapped to the internal Buzzer, 18005851519 sales@ato.com Global Shipping www.ato.com...
  • Page 23: How To Produce An Alarm Signal

    Press the ENT key under M61 for Modification. Use the dot key to skip over these digits that 18005851519 sales@ato.com Global Shipping www.ato.com...
  • Page 24: How To Adjust The Lcd Contrast

    §3.27 How to know how long the battery will last Use M07 to check how long the battery will last. Also please refer to §.2.1 §3.28 How to charge the built-in battery Refer to §2.1 sales@ato.com 18005851519 Global Shipping www.ato.com...
  • Page 25: Menu Window Details

    Window for entering the liner material speed only for non-standard liner materials Window for entering the liner thickness, if there is a liner Window for entering the ABS thickness of the inside wall of the pipe 18005851519 sales@ato.com Global Shipping www.ato.com...
  • Page 26 So there are 36 different flow rate units in total for selection. Window for selecting the totaliziers’ working unit Select totalizer multiplier The multiplier ranges from 0.001 to 10000 Turn on or turn off the NET totalizer 18005851519 sales@ato.com Global Shipping www.ato.com...
  • Page 27 Logger buffer viewer. It functions as a file editor. Use Dot, backspace UP and DN keys to browse the buffer. If the logger is ON, the viewer will automatically refresh once new data are stored Not used Nod used Not used Not used 18005851519 Global Shipping sales@ato.com www.ato.com...
  • Page 28 Not used Work as a keypad and display for another handhold set by RS-232 connected with the handset Not used Date totalizer Not used Not used Not used Not used Not used Not used 18005851519 sales@ato.com Global Shipping www.ato.com...
  • Page 29 All the values are in single accuracy. The drawback is that the user can't operate it by direct key-pressing Not used Not used Not used Not used Entry to hardware adjusting windows only for the manufacturer 18005851519 sales@ato.com Global Shipping www.ato.com...
  • Page 30: Troubleshooting

    (5)Transducer cords are not properly connected Hardware Error Hardware problem Contact the factory (1)Poor signal detected (1)Relocate measuring place (2)Transducers installed (2)Clean the spot PoorSig Detected improperly (3)Check the cords (3)Too much fouling (4)Check the coupler sales@ato.com 18005851519 Global Shipping www.ato.com...
  • Page 31: Other Problems And Solutions

    The battery has not been fully recharged or the recharge has been stopped too many times halfway. There is indeed a time difference between the actual working time and the estimated one, especially when the terminal voltage is in the range 3.70 and 3.90 volt. Please 18005851519 sales@ato.com Global Shipping www.ato.com...
  • Page 32 18005851519 Global Shipping www.ato.com...
  • Page 33: Communication Protocol

    DT(CR) Return date and time yy-mm-dd hh:mm:ss(CR)(LF) M@(CR)*** Send a key value as if a key is pressed LCD(CR) Return the current window display Force the FO output with a frequency in FOdddd(CR) dddd Hz 18005851519 sales@ato.com Global Shipping www.ato.com...
  • Page 34: Protocol Prefix Usage

    2BH, 31H, 32H, 33H, 34H, 35H, 36H, 37H, 45H, 2BH, 30H, 6DH, 33H, 20H. Please note that there will be SPACES (20H) before ‘!’. Prefix W The prefix W should be used in the network environment. The usage format is W + digit string 18005851519 Global Shipping sales@ato.com www.ato.com...
  • Page 35: Codes For The Keypad

    Internet. ASCII ASCII Hexadecimal Decimal Hexadecimal Decimal Code Code Key code Key code Key code Key code 3BH,0BH ◄ 3CH,0CH < MENU 3DH,0DH > ▲/ + ▼/ 18005851519 sales@ato.com Global Shipping www.ato.com...
  • Page 36: Warranty And Service

    For other operational problems, please contact our service department by telephone, fax or email and internet. In most cases, the problem could be solved immediately. §7.2 Software Upgrade Service We provide free-of-charge software upgrade services. Please contact the factory for any lately developed software. sales@ato.com 18005851519 Global Shipping www.ato.com...