§3.2 How to judge the liquid flowing direction................ 16 §3.3 How to change between units systems................16 §3.4 How to select a required flow rate unit................16 §3.5 How to use the totalizer multiplier..................16 §3.6 How to open or shut the totalizers..................16 18005851519 Global Shipping sales@ato.com www.ato.com...
Page 3
6. Communication Protocol......................29 §6. 0 General..........................29 §6.1 Interface Pin-out Definition....................29 §6.2 the Protocol........................29 §6.3 Protocol Prefix Usage.......................30 §6.4 Codes for the Keypad....................... 31 7. Warranty and Service........................32 §7.1 Warranty........................... 32 §7.2 Service..........................32 18005851519 Global Shipping sales@ato.com www.ato.com...
* 4 flow totalizers * Patent balanced lower-voltage multi-pulse * built-in date totalizers ultrasonic igniting * built-in data-logger * Work properly near transverters * 0.5 second totalizing period * 100 Pico-second resolution of time measurement 18005851519 Global Shipping www.ato.com sales@ato.com...
Tdown Tup –Tdown ΔT= §1.4 Parts Identification Converter: 18005851519 Global Shipping sales@ato.com www.ato.com...
Page 7
Top wierw Upstream transducer socket Downstream transducer socket HANDHOLD Front wiew FLOWMETER LCD display ESN=200408008H ULTRASONIC FLOWMETER LED charge indicator ON OFF CHARG E MENU Keypad • Bottom wiew Pins for battery recharge RS232C communication interface 18005851519 Global Shipping www.ato.com sales@ato.com...
Page 8
Transducers: Standard-HM (50mm-700mm) Standard-HS (20mm-100mm) (Optional Accessaries) Cable 5m x2 Red Terminal Red Terminal Blue Terminal Blue Termina Extended Cable 5m x2(Optional Accessaries) Red Terminal Red Terminal Blue Terminal Blue Terminal 18005851519 Global Shipping sales@ato.com www.ato.com...
Each set of the Meinte flow meter has a unique product identification or ESN written into the software that can only be modified with a special tool by the manufacturer. In case of any hardware 18005851519 Global Shipping www.ato.com sales@ato.com...
10 hours of operation. Data Logger Built-in data logger can store over 2000 lines of data Manual Totalizer 7-digit press-key-to-go totalizer for calibration Housing Material Case Size 180x145x40mm Handset Weight 514g (1.2 lbs) with batteries 18005851519 Global Shipping sales@ato.com www.ato.com...
When new pipe parameters have been entered or when the power has been just switched on, the flow meter will enter an adjusting mode to make the signals magnified with proper 18005851519 Global Shipping www.ato.com sales@ato.com...
Each time of the key pressing will proceed to the lower-numbered menu window. For example, if the current window is on M12, the display ▲/ will go to the number M11 window after pressing the key. 18005851519 Global Shipping www.ato.com sales@ato.com...
Other menu windows such as M88 have no functions, or functions were cancelled because they are not applied to this version of the software. 18005851519 Global Shipping sales@ato.com www.ato.com...
▼/ method, and then press key. (8) Press key to enter M24 window to install the transducers on the pipe, and then ▼/ press ey to go to M01 for the results. 18005851519 Global Shipping sales@ato.com www.ato.com...
The actual transducers spacing should be as close as possible to the spacing value. §2.8.2 V-method Installation V-method installation is the moswidely used mode for daily measurement with pipe inner diameters ranging from 20 millimeter to 300 millimeter. It is also called reflective mode or 18005851519 Global Shipping sales@ato.com www.ato.com...
W-method is usually used on plastic pipes with a diameter from 10 millimeters to 100 millimeters T O P V I E W O F P I P E S e n s o r s S p a c i n g 18005851519 Global Shipping sales@ato.com www.ato.com...
Bad sonic coupling for the transducers with the pipe. Try to apply more coupler or clean the surface, etc. Pipes are difficult to be measured. Relocation isrecommended. §2.9.3 Total Transit Time and Delta Time The numbers displayed on menu window M93 are called total transit time and delta time 18005851519 Global Shipping www.ato.com sales@ato.com...
If the transducers are installed properly in the right directions. If the mounting location is good and if the pipe has changed shape or if there is too much fouling inside the pipes Other poor conditions. 18005851519 sales@ato.com Global Shipping www.ato.com...
§3.6 How to open or shut the totalizers Use M34, M35 and M36 to turn on or turn off the POS, NEG, or NET totalizer respectively. §3.7 How to reset the totalizers Use M37 to reset the proper totalizer. 18005851519 sales@ato.com Global Shipping www.ato.com...
The system can be locked without a password or with a one 1 to 4 digit password. With a no- password locking, directly press the ENT key when the password input prompt displays. 18005851519 sales@ato.com Global Shipping www.ato.com...
The totalizer pulse output can only be realized by mapping the pulse output to the OCT or BUZZER hardware devices. For example, assume that the POS totalizer pulse output is needed, and every pulse should represent 0.1cubic meter of liquid flow; the pulse output will be mapped to the internal Buzzer, 18005851519 sales@ato.com Global Shipping www.ato.com...
§3.27 How to know how long the battery will last Use M07 to check how long the battery will last. Also please refer to §.2.1 §3.28 How to charge the built-in battery Refer to §2.1 sales@ato.com 18005851519 Global Shipping www.ato.com...
Window for entering the liner material speed only for non-standard liner materials Window for entering the liner thickness, if there is a liner Window for entering the ABS thickness of the inside wall of the pipe 18005851519 sales@ato.com Global Shipping www.ato.com...
Page 26
So there are 36 different flow rate units in total for selection. Window for selecting the totaliziers’ working unit Select totalizer multiplier The multiplier ranges from 0.001 to 10000 Turn on or turn off the NET totalizer 18005851519 sales@ato.com Global Shipping www.ato.com...
Page 27
Logger buffer viewer. It functions as a file editor. Use Dot, backspace UP and DN keys to browse the buffer. If the logger is ON, the viewer will automatically refresh once new data are stored Not used Nod used Not used Not used 18005851519 Global Shipping sales@ato.com www.ato.com...
Page 28
Not used Work as a keypad and display for another handhold set by RS-232 connected with the handset Not used Date totalizer Not used Not used Not used Not used Not used Not used 18005851519 sales@ato.com Global Shipping www.ato.com...
Page 29
All the values are in single accuracy. The drawback is that the user can't operate it by direct key-pressing Not used Not used Not used Not used Entry to hardware adjusting windows only for the manufacturer 18005851519 sales@ato.com Global Shipping www.ato.com...
(5)Transducer cords are not properly connected Hardware Error Hardware problem Contact the factory (1)Poor signal detected (1)Relocate measuring place (2)Transducers installed (2)Clean the spot PoorSig Detected improperly (3)Check the cords (3)Too much fouling (4)Check the coupler sales@ato.com 18005851519 Global Shipping www.ato.com...
The battery has not been fully recharged or the recharge has been stopped too many times halfway. There is indeed a time difference between the actual working time and the estimated one, especially when the terminal voltage is in the range 3.70 and 3.90 volt. Please 18005851519 sales@ato.com Global Shipping www.ato.com...
Page 32
18005851519 Global Shipping www.ato.com...
DT(CR) Return date and time yy-mm-dd hh:mm:ss(CR)(LF) M@(CR)*** Send a key value as if a key is pressed LCD(CR) Return the current window display Force the FO output with a frequency in FOdddd(CR) dddd Hz 18005851519 sales@ato.com Global Shipping www.ato.com...
2BH, 31H, 32H, 33H, 34H, 35H, 36H, 37H, 45H, 2BH, 30H, 6DH, 33H, 20H. Please note that there will be SPACES (20H) before ‘!’. Prefix W The prefix W should be used in the network environment. The usage format is W + digit string 18005851519 Global Shipping sales@ato.com www.ato.com...
For other operational problems, please contact our service department by telephone, fax or email and internet. In most cases, the problem could be solved immediately. §7.2 Software Upgrade Service We provide free-of-charge software upgrade services. Please contact the factory for any lately developed software. sales@ato.com 18005851519 Global Shipping www.ato.com...