Summary of Contents for CLIVET SCHIARA S.IE1+ME1-Y Series
Page 1
OWNER’S MANUAL Schiara Schiara-SM SPLIT-TYPE ROOM AIR CONDITIONER SCHIARA (for MONOsplit systems): Series S.IE1+ME1-Y from 27M to 35M Series S.IE1+MM1-Y from 53M to 70M SCHIARA-SM (for MULTIsplit systems): Series IE1-XY from 27M to 70M IMPORTANT NOTE: Read this manual carefully before installing for or opera ting your new air conditioning unit.
Page 2
Table of Contents Owner’s Manual Safety Precautions ............04 Unit Specifications and Features ......06 SAFETY FIRST Manual Operation (Without Remote) ....11...
Page 3
Care and Maintenance .............12 Troubleshooting ..............14 European Disposal Guidelines ........18 Wiring diagrams at the end of the manual C au t i o n: Risk of fire (R32/R290 refrigerant) WARNING: Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
Page 4
Safety Precautions Read Safety Precautions Before Installation Incorrect installation due to ignoring instructions can cause serious damage or injury. The seriousness of potential damage or injuries is classified as either a WARNING or CAUTION . This symbol indicates that ignoring instructions may cause death or serious injury.
Page 5
ELECTRICAL WARNINGS Only use the specified power cord. If the power cord is damaged, it must be replaced by the • manufacturer or certified service agent. Keep power plug clean. Remove any dust or grime that accumulates on or around the plug. Dirty •...
Page 6
Unit Specifications and Features Unit Parts Air Filter (pull out) Front Panel Power Cable (Some Units) Louver Remote Control Display window Remote Control Holder “ ” for 3 seconds when: ・ TIMER ON is set ・ FRESH, SWING, TURBO, or SILENCE features are turned on “...
Page 7
Achieving Optimal Performance Optimal performance for the COOL, HEAT, and DRY modes can be achieved in the following temperature ranges. When your air conditioner is used outside of these ranges, certain safety protection features will activate and cause the unit to perform less than optimally. Inverter Split Type FOR OUTDOOR UNITS COOL mode...
Page 8
Wireless Control • (some units) For a detailed explanation of each function, Wireless control allows you to control your air refer to the Remote Control Manual. conditioner using your mobile phone and a Wireless connection. Other Features For the USB device access, replacement, maintenance operations must be carried Auto-Restart •...
Page 9
Setting Angle of Air Flow • Setting vertical angle of air flow While the unit is on, use the SWING/DIRECT button to set the direction (vertical angle) of airflow. Press the SWING/DIRECT button once to activate the louver. Each time you press the button, it will adjust the louver by 6°.
Page 10
Sleep Operation • The SLEEP function is used to decrease energy use while you sleep (and don’t need the same temperature settings to stay comfortable). This function can only be activated via remote control. Press the SLEEP button when you are ready to go to sleep.
Page 11
Manual Operation (Without Remote) How to operate your unit without CAUTION the remote control The manual button is intended for testing In the event that your remote control fails to purposes and emergency operation only. Please work, your unit can be operated manually with do not use this function unless the remote control the MANUAL CONTROL button located on...
Page 12
Care and Maintenance Cleaning Your Indoor Unit When dry, re-clip the air freshening filter to the larger filter, then slide it back into the BEFORE CLEANING OR indoor unit. MAINTENANCE ALWAYS TURN OFF YOUR AIR CONDITIONER SYSTEM AND DISCONNECT ITS POWER Filter Tab SUPPLY BEFORE CLEANING OR MAINTENANCE.
Page 13
Maintenance – CAUTION Long Periods of Non-Use Before changing the filter or cleaning, • If you plan not to use your air conditioner for an turn off the unit and disconnect its power extended period of time, do the following: supply.
Page 14
Troubleshooting SAFETY PRECAUTIONS If ANY of the following conditions occurs, turn off your unit immediately! The power cord is damaged or abnormally warm • You smell a burning odor • The unit emits loud or abnormal sounds • A power fuse blows or the circuit breaker frequently trips •...
Page 15
Issue Possible Causes A rushing air sound may occur when the louver resets its position. The indoor unit makes noises A squeaking sound may occur after running the unit in HEAT mode due to expansion and contraction of the unit’ s plastic parts.
Page 16
Troubleshooting When troubles occur, please check the following points before contacting a repair company. Problem Possible Causes Solution Temperature setting may be higher than ambient Lower the temperature setting room temperature The heat exchanger on the indoor or outdoor unit is Clean the affected heat exchanger dirty Remove the filter and clean it...
Page 17
Problem Possible Causes Solution Wait for the power to be Power failure restored The power is turned off Turn on the power The fuse is burned out Replace the fuse The unit is not working Remote control batteries are Replace batteries dead The Unit’...
Page 18
Error Codes Indoor EEPROM (Electrically Erasable Programmable Read-Only Memory) error Indoor and outdoor unit communication malfunction Indoor fan speed malfunction Indoor room temperature sensor error Evaporator coil temperature sensor error Refrigerant leak detection system malfunction Water level alarm malfunction Dual indoor unit (twin model only) communication malfunction Other twin model malfunction Overload protection...
Page 19
European Disposal Guidelines The manufacturer is registered on the EEE National Register, in compliance with implementation of Directive 2012/19/EU and relevant national regulations on waste electrical and electronic equipment. This Directive requires electrical and electronic equipment to be disposed of properly. Equipment bearing the crossed-out wheelie bin mark must be disposed of separately at the end of its life cycle to prevent damage to human health and to the environment.
Need help?
Do you have a question about the SCHIARA S.IE1+ME1-Y Series and is the answer not in the manual?
Questions and answers