holder (14) using the adjusting screw (17) as required, until the spirit level (4) is central
again.
Working with tripod (recommended): Align the laser beam to the required height. Pro-
ject or check the height at the target location.
Working without the tripod: Establish the height difference between the laser beam and
the height at the reference point. Apply or check the height difference measured at the
target location.
Checking Horizontal/Vertical Lines with the Spirit Levels (see figure G)
The measuring tool can also be used as a carpenter's spirit level for checking vertical and
horizontal lines, for example to align a washing machine or a refrigerator. Position the
measuring tool with the aluminium supporting surface (2) on the surface to be checked.
When placing on horizontal surfaces, the aluminium supporting surface (2) must face
downward; when placing against vertical surfaces, the laser outlet aperture for line
operation (5) must face upward.
Working Advice
Only the centre of the laser point or laser line must be used for marking. The size
u
of the laser point/the width of the laser line changes depending on the distance.
Fastening/Aligning using the Holder
Using the holder (14), the measuring tool can be fastened as follows:
– Line operation: Hanging it by the recess on its rear, place the holder onto a screw
head slightly projecting out of a wall. Use the magnets (9) to fasten the measuring tool
to the metal surface for line operation (15) of the holder. Turn the upper part of the
holder to align the measuring tool as required.
– Point operation: Using the tripod mount (18), place the holder onto the 1/4" thread
of the tripod and screw it tight using the locking screw of the tripod. Align the tripod
roughly. When working without a tripod, place the holder (14) on a surface that is as
level as possible.
Position the measuring tool with the aluminium supporting surface (2) facing down on
the holder. Use the left magnet (9) (viewed from the front side of the measuring tool)
to attach the measuring tool to the metal surface for point operation (16) of the
holder.
Horizontally align the upper part of the holder using the adjusting screw (17) of the
holder and the spirit level for horizontal alignment (4) of the measuring tool. Turn the
upper part of the holder by 90° and repeat the alignment.