Bosch 0603663300 Instructions Manual page 19

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 17
Line laser
B)
Levelling accuracy
Operating temperature
Storage temperature
Max. altitude
Max. relative air humidity
Pollution degree according to IEC 61010-1
Laser class
Laser type
C
6
Divergence
– Laser line
– Laser point
Batteries
Approx. operating time
Weight according to EPTA-Procedure 01:2014
Dimensions (length × width × height)
A) The working range may be reduced by unfavourable environmental conditions (e.g. direct sun-
light).
B) when the measuring tool is positioned correctly(see "Positioning the Measuring Tool
(see figure B)", page 21).
C) Only non-conductive deposits occur, whereby occasional temporary conductivity caused by
condensation is expected.
The serial number (8) on the type plate is used to clearly identify your measuring tool.
Assembly
Inserting/Replacing Batteries (see figure A)
It is recommended that you use alkaline manganese batteries to operate the measuring
tool.
To open the battery compartment cover (10), push it away from the battery compart-
ment in the direction of the arrow. Insert the batteries.
When inserting the batteries, ensure that the polarity is correct according to the illustra-
tion on the inside of the battery compartment.
Bosch Power Tools
English | 19
PLL 1 P
±0.5 mm/m
+5 °C to +40 °C
–20 °C to +70 °C
2000 m
90 %
2
635–650 nm, < 1 mW
0.5 mrad (full angle)
0.6 mrad (full angle)
2 × 1.5 V LR3 (AAA)
15 h
0.14 kg
154 × 24 × 30 mm
1 609 92A 7SC | (24.05.2022)
C)
2
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pll 1 p

Table of Contents