17w - 80w fluorescent maximum security task/ambient luminaire

Advertisement

PHOTOMETRICS
C a n d l e p o w e r D i s t r i b u t i o n
Test No. 5489
FDI-240-120V
250
Lamp=(2) F40T12RS/
Lumens=3200
500
Efficiency=32.9%
750
1000
1250
ORDERING INFORMATION
Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
C a n d l e p o w e r
Deg.
0
1027
5
1059
15
1131
WW
25
1077
35
1017
45
915
55
792
65
466
75
239
85
146
90
124
C o e f f i c i e n t o f U t i l i z a t i o n
rc
80%
rw
70
50
RCR
0
39
39
1
36
35
2
33
31
3
31
28
29
25
4
5
26
22
24
20
6
7
22
18
21
16
8
9
19
15
18
14
10
rc=Ceiling reflectance, rw=Wall reflectance, RCR=Room cavity ratio
CU Data Based on 20% Effective Floor Cavity Reflectance.
Specifications and Dimensions subject to change without notice.
Z o n a l L u m e n S u m m a r y
Zone
Lumens
1027
0-20
356
982
0-40
1078
933
0-60
1752
765
0-90
2081
575
0-120
2108
388
0-180
2108
253
144
78
30
0
70%
30
10
50
30
10
39
39
38
38
38
34
32
34
33
32
29
27
30
29
27
25
24
27
25
23
22
20
25
22
20
20
18
22
19
17
17
15
20
17
15
16
14
18
15
14
14
12
16
14
12
12
10
15
12
10
11
09
13
11
09
%Lamp
%Luminaire
5.6
16.9
16.8
51.1
27.4
83.1
32.5
98.7
32.9
100.0
32.9
100.0
50%
30%
50
10
50
10
36
36
35
35
33
31
31
30
29
26
28
26
26
23
25
22
24
20
23
20
21
17
21
17
19
15
19
15
17
13
17
13
16
12
15
12
14
10
14
10
13
09
13
09
LNL
= LED Night Light (50,000 hrs.)
provided by Cooper
FDI
10%
0%
50
10
0
33
33
33
30
29
28
27
25
24
25
22
21
22
19
19
20
17
16
18
15
14
16
13
13
15
12
11
13
10
10
12
09
09
ADC041578
03/29/2007 1:18:35 PM