Download Print this page

Cooper Lighting Power Failure Emergecny Light ENC Specifications

Entri round clean architectural wall luminaire

Advertisement

Quick Links

INVUE
TM
ENC
ENTRI ROUND
CLEAN
2 6 - 2 5 0 W
M e t a l H a l i d e
W h i t e S O N H i g h P r e s s u r e
S o d i u m
C o m p a c t F l u o r e s c e n t
Q u a r t z H a l o g e n
A R C H I T E C T U R A L W A L L
L U M I N A I R E
• One piece die-cast
aluminum construction.
Accommodates either
up or down mounting
configurations with no
modifications
• One piece die-cast
aluminum faceplate
utilizes a continuous
silicone gasket to seal
securely to housing
• Side hinged faceplate
swings open via release
of one (1) flush mount
die-cast aluminum latch
on housing side panel
• Choice of ten (10) high
efficiency optical systems
• Ballast and related
electrical componentry
are heat sunk to the
housing
• Optional die-cast
aluminum adapter box to
allow for surface conduit
wiring, quartz lamp
options, and emergency
battery pack capability
• Approximate net weight:
13 lbs. (6 kgs.)
1120
COOPER LIGHTING
D E S C R I P T I O N
ENTRI Series' family of modular
faceplate designs provide a
tasteful architectural statement
equally suitable for indoor and
outdoor environments. Available
luminous faceplate window adds
a signature look, while affording
custom color capability.
In downlight only configurations with no
faceplate window.
O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : E N C - 1 5 0 - M H - 1 2 0 - E B - 3 S - B K - L G - L
Lamp
Lamp Type
Product Family
Wattage
MH=Metal Halide
ENC=ENTRI
HID
WS=White SON
Round
1
39=39W
High
Clean
Pressure
70=70W
Sodium
100=100W
CF=Compact
150=150W
Fluorescent
Compact
HL=Quartz
Fluorescent
2
Halogen
26=26W
32=32W
42=42W
52=52W
3
57=57W
4
64=64W
3
84=84W
3
Halogen
5
100=100W
150=150W
250=250W
Optional Luminous Faceplate Insert
14
Options
LG=Luminous Glass Insert
F=Single Fuse (120, 277 or 347V)
LGO=Luminous Glass Insert
with Warm Orange Gel
FF=Double Fuse (208, 240 or 480V)
LGR=Luminous Glass Insert
with Red Gel
DSAB=Dual Fluorescent Switching
LGB=Luminous Glass Insert
with Bright Blue Gel
QAB=Quartz Restrike Adapter Box
LGG=Luminous Glass Insert
EMAB=Quartz Restrike with Delay Adapter Box
with Deep Green Gel
EM/SCAB=Quartz Emergency Separate Circuit
CF/EMAB=Emergency Battery Backup Adapter Box
PC=Button Type Photocontrol
WG=Wire Guard
FRM=Frosted Main Flat Glass
FRS=Frosted Secondary Flat Glass
L=Lamp Included
Certifications
IP66 Rated
U.L. 1598
CSA Listed
40°C Ambient
NOTE: 250W Quartz requires thru-way mounting box. 150W requires
magnetic ballast.
NOTES: 1 All MH lamps are T6 envelope with G12 lamp base. All HPS lamps are T6 envelope with GX12 lamp base. 2 All 26/32/42/57W CF lamps feature a 4-pin lamp
base. Available in CFM and CFG distributions only. 3 Dual compact fluorescent lamps. 4 Nominal M.O.L lamp length of 57W CFL not to exceed 7". 5 All Halogen
lamps are T4 envelope with mini-can base, 120V lamp. 6 WhiteSON HPS lamp available in 100W only. Requires electronic ballast. 120/277V only. Includes use of
VA2001 accessory Thru-way Box. 7 Compact Fluorescent ballasts contain internal fusing. No supplemental fusing is necessary. CF ballasts are 120 through 277V.
Specify with UNV voltage designation. 8 Products also available in non-US voltages and 50Hz for international markets. Consult factory for availability and
ordering information. 9 Dual-tap is 120/277V wired 277V. 10 Multi-tap is 120/208/240/277V wired 277V. 11 Triple-tap is 120/277/347V wired 347V. 12 120 through
277V only. Electronic ballasts contain internal fusing, no supplemental fusing is necessary. Electronic ballast available with all CF lamps, and 39/70/100W MH
lamps. Available with 150W MH lamp. Includes VA2001 accessory Thru-way Box. Not available with QAB or EMAB options. 13 Custom and RAL color matching
available upon request. Consult your INVUE Lighting Systems Representative for further information. 14 Add as suffix in the order shown. 15 Dual switching
requires dual 26, 32 or 42W Compact Fluorescent lamps. Allows independent switching control of each lamp through use of two (2) electronic ballasts. Allows
50% power reduction when dual ballasts are independently wired and controlled. 16 CF lamps only. Battery backup operates 90 minutes at minimum 32°F (0°C),
42W maximum. 17 For use in down lighting applications only. 18 Frosted secondary lens provided standard on 3SG, FTG, and CFG distributions. 19 Order
separately, replace XX with color suffix. 20 Specifications and dimensions subject to change without notice.
D I M E N S I O N S
15 25/32" [400 mm]
Voltage
8
Ballast
120=120V
MB=Magnetic
208=208V
EB=Electronic
240=240V
Ballast
12
277=277V
X=None
6
347=347V
(for Halogen
480=480V
Lamp)
7
DT=Dual-Tap
Wired 277V
9
MT=Multi-Tap
Wired 277V
10
TT=Triple-Tap
Wired 347V
11
UNV=120-277V
Universal
Electronic
Ballast
14
Specify Voltage
Specify Voltage
Control Adapter Box
15
(Also Strikes at Cold Start)
Adapter Box
(Specify 120 or 277V)
16
(specify voltage)
17
18
(Standard for all Halogen lamps)
FCO
Full Cutoff
ISO 9001
7 3/4"
[196 mm]
8 1/8" [206 mm]
Colors (add as
Optical System
suffix/must specify)
Downlight or
BK=Black
Uplight (HID or
AP=Grey
Halogen)
BZ=Bronze
3S=Type III
WH=White
FT=Forward
DP=Dark Platinum
Throw
GM=Graphite Metallic
FX=Wall Grazing
Optic
TS=Tight Spot
Downlight and Uplight (HID and Halogen)
3SG=Type III, 90% Main/10% Secondary
Glow
3SP=Type III with Pencil Secondary
FTG=Forward Throw, 90% Main/
10% Secondary Glow
FTP=Forward Throw with Pencil Secondary
FXF=Wall Grazing Optic, 50% up/50% Down
TSF=Tight Spot, 50% up/50% Down
Compact Fluorescent
CFG=90% Main + 10% Secondary Glow
CFM=100% Main, Up or Downlighting
Accessories
19
VA2001-XX=Thru-way Box
VA2002-XX=Wire Guard Kit
ENC
WATTAGE TABLE
39, 70, 100, 150W
Metal Halide
100W
White Son HPS
26, 32, 42, 57W
Compact Fluorescent
(2) 26, (2) 32, (2) 42W
Dual Compact Fluorescent
100, 150, 250W
Quartz Halogen
Options &
13
Accessories
(See Below)