! IMPORTANT ! Safety Notes 1. Mounting of the drive should be carried out by a D+H distributor, whose qualification and experience is ensured by regular in-house training. 2. All wiring must be installed by a qualified electrican according to National Electrical Codes, NFPA 70.
Technical data Type VCD 204/yyy Power supply 24 V DC / ± 20 % Nominal current 0.35 A Nominal force 200 N (45 lbf) Nominal locking force approx. 2000 N (449.6 lbf) (excluding bracket) Service life >20 000 double strokes Duty cycle 30 % (With cycle time 10 minutes) Housing...
Page 4
Dimensions Stroke limiting with magnets When using two VCD 204 on one window , both drives must be electrically connected in order to set the stroke , although only one drive needs to be switched to the stroke learning mode with the magnet .
Maintenance and cleaning Guarantee Maintenance work is only allowed when the device is in You will get 2 years guarantee for all D+H products a de-energized condition! Inspection and maintenance from date of verified handing over of the system up to...
Page 6
Pin Assigment Mot. a Mot. b (WH) (BN) (BN) brown (YE) yellow (GN) green (WH) white (PK) pink (GY) grey Standard Optional signals -SA-SZ -SGI -SKS WH (Mot. a) WH (Mot. a) WH (Mot. a) WH (Mot. a) YE (TMS+/BRV) YE (TMS+/BRV) YE (TMS+/BRV) YE (TMS+/BRV)
Page 7
Connection Gegen Kurzschluss sichern / Protect against short circuit / VCD 204/yyy Protéger contre les courts-circuits / Proteger contra cortacircuitos TMS+ / (YE) Mot. b (BN) Abzweigdose / Junction box / Mot. a (WH) Boîte de dérivation / 1 Antrieb / 1 drive / Caja de conexión 1 motorisation / 1 motore max.