Download Print this page

Graco E Series Instructions-Parts List Manual page 10

Airless spray gun
Hide thumbs Also See for E Series:

Advertisement

11
20
28a
23
18
28
Fig. 4
14
6
10
5
Fig. 5
10
307260
Service
8
See Fig. 4 and Fig. 5.
1. Relieve the pressure, and disconnect the hose.
9
22
2
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
16
Pressure Relief Procedure on page 6.
15
2. Remove the tip/guard assembly (18, 28) and the
tip gasket (28a).
7
3. Unscrew the nut (21). Remove the trigger
13
guard (23).
4. Unscrew the nipple (20).
21
5. Remove the locknut (9) and screw (8).
6. Swing the trigger (11) out of the way. Unscrew the
packing nut (6). Remove the valve stem (14). Use a
wire hook to pull the packings (10) and gland (5) out
03959A
of the body (22). See Fig. 5.
7. Unscrew the lower body (13) from the upper body.
Remove the spring (15), retainer (16), and ball (2).
See Fig. 4.
8. Clean and inspect parts. Replace worn or
damaged parts. Disassemble and manually clean
the tip/guard assembly (18, 28) if they are dirty.
11
NOTE: Always replace all four packings (10) and the
gland (5) at the same time.
9. Install the support (7), spring (15), retainer (16) and
ball (2) in the lower body (13). Screw the lower body
firmly into the upper body (22). See Fig. 4
10. Lubricate the packings (10) and gland (5). Install
these parts one at a time into the gun body (22).
Install the valve stem (14) and packing nut (6).
See Fig. 5.
11. Flip the trigger down and install the screw (8) and
03962A
locknut (9).
12. Screw the nipple (20) into the gun body (22).
13. Install the trigger guard (23) and secure with the
locknut (21).
14. Reinstall the tip gasket (28a) and the tip/guard
assembly (18, 28).
15. Adjust the trigger before using the gun. See
Adjusting the Trigger, on page 11.
WARNING