Download Print this page

Graco E Series Instructions-Parts List Manual

Airless spray gun
Hide thumbs Also See for E Series:

Advertisement

Quick Links

Parts
INSTRUCTIONS-PARTS LIST
INSTRUCTIONS
Airless Spray Gun
4500 psi (31 MPa, 310 bar) Maximum Working Pressure
Model 210890, Series E
This manual contains important
warnings and information.
READ AND KEEP FOR REFERENCE.
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441
ECOPYRIGHT 1976, GRACO INC.
Graco Inc. is registered to I.S. EN ISO 9001
307260
First choice when
quality counts.t
07413A
Rev. L

Advertisement

loading

Summary of Contents for Graco E Series

  • Page 1 INSTRUCTIONS Airless Spray Gun 4500 psi (31 MPa, 310 bar) Maximum Working Pressure Model 210890, Series E 07413A GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 ECOPYRIGHT 1976, GRACO INC. Graco Inc. is registered to I.S. EN ISO 9001...
  • Page 2 D This equipment is for professional use only. D Read all instruction manuals, tags, and labels before operating the equipment. D Use the equipment only for its intended purpose. If you are uncertain about usage, call your Graco distributor. D Do not alter or modify this equipment. Use only genuine Graco parts and accessories.
  • Page 3 WARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor air ventilation, open flames, or sparks can cause a hazardous condition and result in fire or explosion and serious injury. D Ground the equipment and the object being sprayed. See Ground the System on page 4. D Provide fresh air ventilation to avoid the buildup of flammable fumes from solvent or the fluid being sprayed.
  • Page 4 Installation Ground the System D Fluid hoses: Use only grounded hoses with a WARNING maximum of 500 feet (150 m) combined hose length to ensure grounding continuity. FIRE EXPLOSION HAZARD D Spray gun: Obtain grounding through connection to Before operating, ground the system as explained below.
  • Page 5 Installation NOTE: Numbers and letters in parenthesis in the text 4. With the gun safety latch engaged, unscrew the correspond to the reference numbers and letters in the retaining nut (B) of the tip/guard assembly text and drawings. (18, 28), and install the gasket (28a) in the retaining nut.
  • Page 6 Fluid under high pressure can be in- should an injection injury occur. Additional cards jected through the skin and cause are available at no charge from Graco Inc. serious injury. To reduce the risk of an injury from injection, splashing fluid, or moving 1.
  • Page 7 Operation Adjusting the Spray Pattern CAUTION WARNING Openings in the tip guard are designed to reduce paint buildup on the guard while spraying. Any To reduce the risk of a fluid injection injury, never damage to the sharp edges of the openings causes use the gun with the tip guard or trigger guard paint to collect at that area.
  • Page 8 Operation Flushing If Valve Will Not Stop Spraying NOTE: Flush the gun before the fluid being spraying Check the clearance between the tip of the trigger and can dry in it. the safety latch. See Adjusting the Trigger on page 11.
  • Page 9 Notes 307260...
  • Page 10 Service See Fig. 4 and Fig. 5. 1. Relieve the pressure, and disconnect the hose. WARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 6. 2. Remove the tip/guard assembly (18, 28) and the tip gasket (28a).
  • Page 11 Service Adjusting the Trigger See Fig. 6. WARNING Proper adjustment of the trigger is essential to be sure the gun trigger safety makes the gun inopera- 0.123” (3.18 mm) free play tive when engaged. Improper adjustment may allow the gun to be triggered even with the gun trig- ger safety locked, resulting in serious injury, includ- ing fluid injection and splashing in the eyes or on the skin.
  • Page 12 Parts Model 210890, Series D Ref. Part No. Description Qty. 101514 PIN, cotter; 0.06 (1.6 mm) dia; 1.25 in. (32 mm) long 2*† 101701 BALL, carbide; 0.25 (6.4 mm) dia 150496 PIN, pivot 150497 LINK, pivot pin 5† 150501 GLAND, male; piston packing 150503 NUT, packing;...
  • Page 13 Technical Data Category Data Maximum working pressure 4500 psi (31 MPa, 310 bar) Fluid valve orifice size 0.188 in. (4.78 mm) dia. Length 4.5 in. (114 mm) Height 7.0 in. (178 mm) Width 1.5 in. (38 mm) Weight 2.0 lb (0.9 kg) Wetted parts Zinc-plated steel, alloy steel, tungsten carbide, thiokol impregnated leather, Delrin...
  • Page 14 Notes 307260...
  • Page 15 Notes 307260...
  • Page 16 Graco distributor to the original purchaser for use. With the exception of any special extended or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.

This manual is also suitable for: