Problem
Power On:
the "Power
On"/"Ready" LED is
not lit
On line Mode:
EXT TRIGGER LED
is not lit (when
external trigger
activates)
On line Mode:
EXT TRIGGER LED
is correctly lit but
nothing happens (no
reading results)
Serial On line
Mode:
the reader is not
triggered (no reading
results)
On line Mode and
Serial On Line:
Reader doesn't
respond correctly to
the expected
external signals end
28
TROUBLESHOOTING GUIDE
Suggestions
Is power connected?
If using a power adapter (like PG 220), is it connected
to wall outlet?
If using rail power, does rail have power?
If using C-Box 100, does it have power (check switch
and LED)? (DS1100 10 – 30 Vdc versions only)
Measure Voltage at pin 13 and pin 25
Ιs sensor connected to EXT TRIG pins (19 and 22)?
Is power supplied to photo sensor?
Are the photo sensor LEDS (if any) working correctly?
Is The sensor/reflector system aligned?
Is the software configuration consistent with the
application
In the WinHost program select the OPERATING MODE
tab and check for related parameters
In the WinHost program select the OPERATING MODE
tab and check if serial on line is enabled as operating
mode
Are the Start – Stop characters correctly assigned?
Is the serial trigger source correctly connected and
configured?
In the WinHost program select the OPERATING MODE
tab and check the TIMEOUT parameterisation.
condition
(operating
DS1100
mode
etc.)?