5
Problem
Power On:
the "Power
On"/"Ready" LED is
not lit
On line Mode:
EXT TRIGGER LED
is not lit (when
external trigger
activates)
On line Mode:
EXT TRIGGER LED
is correctly lit but
nothing happens (no
reading results)
Serial On line
Mode:
the reader is not
triggered (no reading
results)
On line Mode and
Serial On Line:
Reader doesn't
respond correctly to
the expected
external signals end
28
TROUBLESHOOTING GUIDE
Suggestions
•
Is power connected?
•
If using a power adapter (like PG 220), is it connected
to wall outlet?
•
If using rail power, does rail have power?
•
If using C-Box 100, does it have power (check switch
and LED)? (DS1100 10 – 30 Vdc versions only)
•
Measure Voltage at pin 13 and pin 25
•
Ιs sensor connected to EXT TRIG pins (19 and 22)?
•
Is power supplied to photo sensor?
•
Are the photo sensor LEDS (if any) working correctly?
•
Is The sensor/reflector system aligned?
•
Is the software configuration consistent with the
application
In the WinHost program select the OPERATING MODE
tab and check for related parameters
•
In the WinHost program select the OPERATING MODE
tab and check if serial on line is enabled as operating
mode
•
Are the Start – Stop characters correctly assigned?
•
Is the serial trigger source correctly connected and
configured?
•
In the WinHost program select the OPERATING MODE
tab and check the TIMEOUT parameterisation.
condition
(operating
DS1100
mode
etc.)?