Quick SBC 1100 NRG+ FR Manual Of Installation And Use

Quick SBC 1100 NRG+ FR Manual Of Installation And Use

High power
Hide thumbs Also See for SBC 1100 NRG+ FR:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

High Quality Nautical Equipment
SBC NRG
HIGH POWER
SBC 1100 NRG+ FR
SBC 1200 NRG+ FR
SBC 1450 NRG+ HR
SBC 1950 NRG+ HR
SBC 2450 NRG+ HR
Manuale di installazione ed uso
IT
Manual of installation and use
EN
+
CARICABATTERIE SBC NRG+
SBC BATTERY CHARGER NRG+
REV 001
b

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SBC 1100 NRG+ FR and is the answer not in the manual?

Questions and answers

Summary of Contents for Quick SBC 1100 NRG+ FR

  • Page 1 REV 001 High Quality Nautical Equipment SBC NRG HIGH POWER SBC 1100 NRG+ FR SBC 1200 NRG+ FR SBC 1450 NRG+ HR SBC 1950 NRG+ HR SBC 2450 NRG+ HR Manuale di installazione ed uso CARICABATTERIE SBC NRG+ Manual of installation and use...
  • Page 3 INDICE Pag. 4 CARATTERISTICHE E INSTALLAZIONE Pag. 5 INSTALLAZIONE: ambiente di installazione Pag. 6/7 INSTALLAZIONE: alimentazione dell’apparecchio Pag. 8 INSTALLAZIONE: caricabatterie singolo / caricabatterie in parallelo - Segnali di controllo Pag. 9 INSTALLAZIONE: stato semplificato caricabatterie - Sensore temperatura batteria Pag.
  • Page 4: Installazione

    • Possibilità di collegare in parallelo fino a 3 caricabatterie dello stesso modello tramite controllo digitale per la ripartizione di corrente. • Bassa ondulazione residua sull’uscita. • Ingresso rete AC Universale 264 ÷ 83 Vac, 45 ÷ 66 Hz (solo modelli SBC 1100 NRG+ FR e SBC 1200 NRG+ FR). ϕ • Fattore di potenza (cos ) pari a 1.
  • Page 5: Ambiente Di Installazione

    INSTALLAZIONE EQUIPAGGIAMENTO NECESSARIO PER L’INSTALLAZIONE A seconda del modello utilizzare le batterie e i cavi sui terminali di uscita specificati nella seguente tabella: MODELLO SBC 1100 NRG+ FR SBC 1200 NRG+ FR SBC 1450 NRG+ HR SBC 1950 NRG+ HR...
  • Page 6 AC e tramite staccabatteria dalle batterie. ATTENZIONE: nel caso in cui il cavo di alimentazione sia danneggiato, farlo sostituire da un centro assistenza Quick . Per evitare incidenti l’apparecchio deve essere aperto solo da personale autorizzato.
  • Page 7 INSTALLAZIONE FIG.2A STACCABATTERIE BATTERIA BATTERIA BATTERIA N° 3 N° 2 N° 1 FIG.2B L1 = L2 = L3 inferiore a 2 m L inferiore a 6 m BATTERIA ATTENZIONE: durante la carica le batterie possono generare gas esplosivi. Evitare scintille o fiamme. Provvedere ad un’adeguata ventilazione dell’ambiente batterie durante la carica.
  • Page 8 INSTALLAZIONE CARICABATTERIE SINGOLO Il polo positivo della batteria o del gruppo batterie deve essere collegato a uno dei terminali positivi del caricabatterie; il polo negativo della batteria o del gruppo batterie al terminale negativo del caricabatterie (Fig.1A). Per effettuare i collegamenti utilizzare il connettore in dotazione con l’apparecchio. Se si hanno solamente uno o due gruppi di batterie, collegare sempre l’uscita siglata come “MASTER”.
  • Page 9 INSTALLAZIONE STATO SEMPLIFICATO CARICABATTERIE Sul pin 4 della presa RJ45 CAN OUT è presente un segnale che fornisce l’indicazione sullo stato di funzionamento del cari- cabatterie (presenza o assenza di problemi) (Fig 4). FIG. 4 COLLEGAMENTO STATO PIN 4 CAN OUT Caricabatterie spento o presenza di ALTA IMPEDENZA problemi con reset manuale.
  • Page 10 INSTALLAZIONE COLLEGAMENTO RETE CAN BUS CARICABATTERIE IN PARALLELO Di seguito si riporta un esempio di collegamento della rete per caricabatterie collegati in parallelo (modalità di ripartizione di corrente): SBC NRG+ HI POWER SBC NRG+ HI POWER CONNETTORE TERMINAZIONE CAN IN CAN OUT CAN IN CAN OUT RDS 1562 CONNETTORE...
  • Page 11: Funzionamento

    FUNZIONAMENTO FUNZIONAMENTO PANNELLO DI CONTROLLO Il pannello di controllo è composto da 6 LED: n° 1 LED STATUS, n°1 LED ERROR, n° 4 LED OUT CURRENT LED STATUS LED ERROR LED OUT CURRENT Le indicazioni fornite dai LED sono riportate di seguito: LED STATUS COLORE LED DESCRIZIONE...
  • Page 12 FUNZIONAMENTO CARATTERISTICHE DI CARICA La carica avviene attraverso 3 fasi: Fase BULK (corrente costante) Le batterie richiedono più corrente di quanto il caricabatterie possa fornire. La corrente viene limitata al valore nominale massimo di uscita o ad un valore inferiore se sono presenti fattori che determinano una riduzione di potenza dell’apparecchio.
  • Page 13 Probabile inversione di polarità nel collegamento delle batterie ai morsetti di uscita del Fusibile di uscita interrotto caricabatterie. Il problema richiede una verifica da parte di un centro assistenza Quick ® Protezione software. Il caricabatterie a causa di un malfunzionamento interno ha erogato, per un brevissimo Sovratensione in uscita istante, una tensione superiore al valore nominale.
  • Page 14: Manutenzione

    L’erogazione della massima corrente di uscita riprenderà quando la tensione di rete ritornerà ad un valore superiore a 207 Vac (mod. SBC 1450 NRG+ HR, SBC 1950 NRG+ HR HR, SBC 2450 NRG+ HR) o 108 Vac (mod. SBC 1100 NRG+ FR, SBC 1200 NRG+ FR). AC assente La tensione di rete AC è...
  • Page 15: Dati Tecnici

    DATI TECNICI CARATTERISTICHE TECNICHE MODELLO SBC 1100 NRG+ FR SBC 1200 NRG+ FR SBC 1450 NRG+ HR SBC 1950 NRG+ HR SBC 2450 NRG+ HR CARATTERISTICHE DI USCITA 80 A 100 A 60 A 80 A 100 A Corrente di uscita massima •...
  • Page 16: Installation

    • Possibility to connect in parallel up to three battery chargers of the same model for current sharing by means of digital control. • Low residual fluctuation on output. • Universal AC supply input 264 ÷ 83 Vac, 45 ÷ 66 Hz (only models SBC 1100 NRG+ FR and SBC 1200 NRG+ FR). ϕ • Power factor (cos ) equal to 1.
  • Page 17: Necessary Equipment For Installation

    INSTALLATION NECESSARY EQUIPMENT FOR INSTALLATION Depending upon model, use the batteries and cables on the output terminals as specified in the following table: MODEL SBC 1100 NRG+ FR SBC 1200 NRG+ FR SBC 1450 NRG+ HR SBC 1950 NRG+ HR...
  • Page 18 AC mains and by means of a battery isolator from the batteries. WARNING: in cases where the AC power cord could be damaged, have this changed by a “Quick ” service centre.
  • Page 19 INSTALLATION FIG.2A BATTERY SWITCHES BATTERY BATTERY BATTERY N. 3 N. 2 N. 1 FIG.2B L1 = L2 = L3 shorter than 2 meters L shorter than 6 meters BATTERY WARNING: during charge, batteries can generate explosive gases, therefore avoid sparks or naked flames. Provide adequate ventilation to the battery area whilst charging.
  • Page 20: Control Signals

    INSTALLATION SINGLE BATTERY CHARGER The positive terminal of the battery or of the group of batteries must be connected to one of the positive terminals of the battery charger. The negative terminal of the battery or of the group of batteries must be connected to the nega- tive terminal of the battery charger (fig.
  • Page 21: Battery Temperature Sensor

    INSTALLATION BATTERY CHARGER’S SIMPLIFIED STATUS On pin 4 of the RJ45 CAN OUT socket, a signal which indicates the operating status of the battery charger (presence or absence of problems) is located (Fig. 4). FIG. 4 PIN 4 CAN OUT STATE CONNECTION Battery charger switched off or presence...
  • Page 22 INSTALLATION CONNECTION TO THE BATTERY CHARGER CAN BUS NETWORK IN PARALLEL Here following is an example of network connection for battery chargers connected in parallel (current sharing mode): SBC NRG+ HI POWER SBC NRG+ HI POWER TERMINATION CONNECTOR CAN IN CAN OUT CAN IN CAN OUT RDS 1562 TERMINATION...
  • Page 23: Operation

    LED COLOUR DESCRIPTION No mains power or active errors GREEN FLOAT phase ORANGE ABSORPTION phase BULK phase QUICK FLASH Active power reduction SLOW FLASH Active charge compensation SHORT GREEN PULSE Active monitor mode GREEN PULSE Active Stand-by mode LED ERROR...
  • Page 24: Charging Characteristics

    OPERATION CHARGING CHARACTERISTICS Charging procedure takes place in 3 phases: BULK phase (constant current) The batteries need more current than the battery charger can supply. Current is limited to the maximum rated output or to a lower value if factors which determine a power reduction of the device are present. The battery charger can enter this phase during start-up, when the batteries are low or when a high load is connected.
  • Page 25 FLASHES Likely inversion of polarity in the connection of the batteries to the battery charger’s output Output fuse open terminals. The problem requires a check by a Quick service center. ® Software protection. The battery charger, due to an internal malfunction, supplied for a very short time a higher Output overvoltage voltage than the rated value.
  • Page 26: Maintenance

    The supply of the maximum output current will start again once the network voltage increase back to a higher value than 207 Vac (mod. SBC 1450 NRG+ HR, SBC 1950 NRG+ HR HR, SBC 2450 NRG+ HR) or 108 Vac (mod. SBC 1100 NRG+ FR, SBC 1200 NRG+ FR). AC fail The AC mains voltage is lower than 161 Vac (mod.
  • Page 27: Technical Data

    TECHNICAL DATA TECHNICAL DATA MODEL SBC 1100 NRG+ FR SBC 1200 NRG+ FR SBC 1450 NRG+ HR SBC 1950 NRG+ HR SBC 2450 NRG+ HR OUTPUT CHARACTERISTICS 80 A 100 A 60 A 80 A 100 A Maximum output current •...
  • Page 28 DIMENSIONI - DIMENSIONS mm (inch) 110 (4 170 (6 81,5 (3 SBC NRG HIGH REV001B...
  • Page 29 SBC NRG+ SERIES SBC NRG+ 12V SBC NRG+ 24V SBC NRG HIGH REV001B...
  • Page 30 NOTES...
  • Page 32: High Power

    SBC NRG+ R001 HIGH POWER Codice e numero seriale del prodotto Product code and serial number QUICK S.p.A. - Via Piangipane, 120/A - 48124 Piangipane (RA) - ITALY ® Tel. +39.0544.415061 - Fax +39.0544.415047 www.quickitaly.com...

Table of Contents