Hager EK005, 25505 - Room Thermostat With Separate Probe Manual

Hager EK005, 25505 - Room Thermostat With Separate Probe Manual

Advertisement

Hager EK005, 25505 - Room Thermostat With Separate Probe Manual

Product presentation

The EK005, 25505 is an electronic room thermostat particularly suitable for floor or ceiling heating thanks to its separate probe.

Adjustable temperature's range:
Draw back the knob for temperature range adjustment.
Adjustable temperature's range

Electrical connection

Electrical connection

Temperature's range limitation

It is possible to limit mechanically the temperature's range (between 10° to 40°C for example) or even to lock the temperature range at a fixed temperature (30°C for example).
For that:

  1. Take the two range limiting nibs which are found in the thermostat base.
    Temperature's range limitation - Step 1
  1. Locate the knob to indicate a precise value (30°C for example) and remove it.
  2. Place the two range limiting nibs.
    Temperature's range limitation - Step 2

Ex : to lock the temperature's range at 30°C

  1. Put back the knob and check that the temperature's range is limited to the requested values.

Installation of the probe

 Installation of the probe

Application example:

  • protected by a sheath for the control of floor temperature.
  1. heating frame
  2. probe.

warning

  • This device must be installed only by a qualified electrician.
  • Conform to TBTS installation rules.

Installation

The thermostat can be installed either surface mounted or on a flush box 60 mm.
Cables should arrive from the back.

Installation

  • take off the front cover
  • fix the product's base through the fixing holes
  • connect the wires on the terminals
  • put back the front cover
  • indicating light to signal heating.
  • switch ON/OFF.

Technical specifications

Electrical characteristics

  • Supply: 230V M ±15% 50/60 Hz
    240V~+/-6% 50/60Hz
  • Output:
  • 1 opening contact
  • Switching capacity: µ16A / 230V~ AC1
  • Resistive load: 16A / 230V~
  • Consumption: 0,5 VA
  • Voltage and current declared for the needs of EMC emission test 230V~ / 0.5A
  • Pollution category: 2
  • Rated impulse voltage: 4kV
  • Software structure: class A
  • Action type: 2B
  • Upstream protection: circuit breaker 16A
  • Insulation class: II
    Independent installation device for built-in installation

Functional characteristics

  • ON/OFF regulation
  • static differential < 1K
  • dimensions: 80 x 80 x 30
  • Ecodesign class: 1

Environment

  • Operating temperature: 0°C to +35°C
  • Storage temperature: -10°C to +65°C
  • Protection degree: IP 30.

Connection

Flexible: 1 to 2,5
Rigid: 1,5 to 4

Caracteristics of the probe

  • cable length: 4 m
  • maximum length: 50 m
  • cable section: 0,75 mm2
  • insulation classe: II
  • protection class: IP 54

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Hager EK005, 25505 - Room Thermostat With Separate Probe Manual

Advertisement

Need Assistance?

Do you have a question about the EK005, 25505 that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents