Advertisement
The Tester is a handheld and battery operated very convenient small.
Tool that is specially used to measuring SMD (Surface Mounting Device), there are Chip type resistor, Chip type capacitor and diode, for example.
Moreover, the Tester have the continuity checking function The Tester is automatically identified the passive Component as has been indicated above. Therefore, the measurement are allowed by fully automatic detection. The Tester is designed to meet IEC1010-1 standard and Stipulation of 2-Poulation Grade. The Tester conform to the European Union's following Requirement: CE regulation 89/336 (EMC Electromagnetic Compatibility).
The entire outer surface of the Tester case has been with thermo plastic elastomer, and the two testing pins has been gold-plated, so that it is reduce pin contact resistance and prevent to get rusty.
This operating instruction covers information on safety and caution, so please read relevant information carefully and observe all the warming and note strictly.
Check the Meter and accessories thoroughly before using the Meter. Contact your local distributor if the Meter or any components are damaged or malfunction.
The following safety notes should be observed prior to using This Tester and any associated accessory. Although the Tester do not used to measuring DC/AC Voltage or Current, but there are situations where hazardous condition may be present.
Never use the Tester on alive circuits.
[1] "FUNC": it is the function select key that acts trigger.
Use the Push Button as switch of Resistanc/ Capacitance/Diode/Continuity. The Tester is have not Power Key. When install the 3V Lithium Battery, the Tester immediately power ON.
Once powered on, the Tester will perform the Scanning Mode and then the 'SCAN' and ' - - - - ' sign is displayed on the LCD. This is indicate the Tester is inter to the auto scanning mode and will be automatically identify the resistor, capacitor, diode and continuity measurement mode.
The 'FUNC' Button is used to selecting some one measurement mode manually.
[2] "HOLD": Press "HOLD" Button to enter or exit the hold mode In any measurement mode. This key is act with trigger. In the data hold mode, the Tester stop updating LCD, stored current measuring data and displayed the measured data, and then holding the data until press the "HOLD" key once again.
Note: after auto power-OFF is active, pushing any of the push button can turn on the Tester again.
NO | Indicator | Meaning |
1 | SCAN | Auto Scanning Mode |
2 | AUTO | Auto Ranging |
3 | ![]() | Data Hold |
4 | ![]() | Diode checking Mode |
5 | ![]() | Continuity Checking Mode |
6 | numF | Capacitance Units(nF, uF, mF) |
7 | MKΩ | Resistance Units(Ω, KΩ, MΩ) |
8 | ![]() | Low Battery Indicator |
Function | Range | Best Resolution | Accuracy |
Resistance | 300Ω/3KΩ/ 30KΩ/300K /3MΩ 30MΩ | 0.1Ω | ±(1%rdg+ 2dgt) ±(1.2%rdg+ 3dgt) |
Capacitance | 3nF/30nF/300nF/ 3uF/30uF/ 300uF/3mF /30mF | 1pF | ±(2%rdg+ 3dgt) ±(3%rdg+ 3dgt) |
Diode Check | Open Voltage: 2.8V Testing Current: 2mA | ||
ContinuityCheck | When the resistance is less than 30Ω, the Buzzer is sounded. |
Accessory:
When install the 3V Lithium Battery, the Tester immediately power ON. In this case, the 'SCAN' and ' - - - - ' sign is displayed on the LCD. This is indicate the Tester is inter to the auto scanning mode and automatically identified the resistor, capacitor, diode and continuity, and then enter to the corresponding measurement mode.
In the Scanning Mode, when two pins are in touch with the object being measured, the measured value will be displayed on the LCD.
[1] Auto scanning Mode & Auto range:
300.0Ω - 3.000MΩ
[2] Selected Resistance measurement Mode by the "FUNC" key:
The range is extended to 30 MΩ, i.e.300.0Ω-30.00MΩ
When over load, the 'OL' symbol will be displayed on the LCD.
[1] Auto scanning & Auto range: 3.000nF - 300.0uF.
[2] Selected Capacitance Mode by the 'FUNC' key: The range is extended to 30.00mF, i.e.
3.000nF-30.00mF.
To avoid damage to the Meter or to the equipment under test, disconnect power and discharge all high-voltage capacitors before measurement capacitance.
You can selecting the Scanning Mode or the Diode Mode by The 'FUNC' push button.
May selecting Scanning Mode or Continuity Mode by 'FUNC' push button.
When the resistance reading is less than 30Ω, the buzzer generates 2KHz beep to indicate continuity.
When meter display , the battery must be replace to maintain normal operation.
Note:
Lithium Battery type: 3V CR2032
The meter can be cleaned with soft clean cloth to remove any oil, grease or grim.
Do not use liquid solvent or detergent.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Advertisement
Need help?
Do you have a question about the MS8910 and is the answer not in the manual?
Questions and answers