Sharp R-22AM Service Manual page 32

Hide thumbs Also See for R-22AM:
Table of Contents

Advertisement

R-22AM
R-23AM
R - 2 3 A T
2) How to enter the memory information
Example : Suppose cooking time 5 sec. and output power
100% are entered into the memory pad 1.
PAD ORDER
(Door close)
SET
SET
"NUMBER" •
(within 2 sec.)
1
NUMBER 1 • 0
5
NUMBER 1 • 5
SET
"NUMBER" •
SET
Enter the memory information into the memory pads 1 ~ 10
referring to above example. The memory information are
given below.
Memory No.
Cook Time
1
5 sec.
2
10 sec.
3
20 sec.
4
30 sec.
5
40 sec.
6
50 sec.
7
1 min.
8
1 min.15 sec.
9
1 min.30 sec.
10
2 mins.
11-20
0 sec.
3) How to enter the EEPROM data
Enter the EEPROM data into the memory pads, 3, 4, 6, 8,
9, 11, 12, 13, 14, 15 and 20, referring to following example
and the table of EEPROM data.
Example : Suppose the EEPROM data "2235" is entered
into the memory pad 3.
PAD ORDER
(Door close)
CHECK
"NUMBER" •
CHECK
#2
(User's Total Counts)
#1 VOLUME
#2
VOLUME
#2
DOUBLE
#3
QUANTITY
(Total Counts of Service)
3
SET
2,2,3,5
SET
CHECK
#1: Denotes the procedure for the servicer to disable
clearing. This procedure is instructed to service per-
sonnel only and is excluded from the operation manual.
#2: If IC-2 is exchanged, 0 should be indicated instead of
8268. But if the control unit is exchanged, 0 is not
always indicated.
#3: Total counts of service, 6 figures will be displayed.
DISPLAY
PHONE
Output Power
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
"
" : Flicker /
: 0.1 sec BUZZER
DISPLAY
PHONE
CHECK
82 68
"CHECK"
82 68
"CHECK"
82 68
"CHECK"
XXXXXX
"CHECK"
30 30
"CHECK"
0
"CHECK"
22 35
"CHECK"
x 4
22 35
"CHECK"
Table of EEPROM data
Memory
Data
Pad
3
2 2 3 5 Higher temperature limit setting of
magnetron thermistor detection
4
0 0 0 0 Constant setting of fan lock detection
6
0 1 0 0 Time setting of fan lock detection
8
3 2 0 0 Higher temperature limit setting of
exhaust air detection
9
0 0 0 0 Constant setting of fan lock detection
11
0 0 0 0 Constant setting of magnetron
thermistor detection
12
0 0 0 0 Constant setting of magnetron
thermistor detection
13
0 0 0 0 Constant setting of magnetron
thermistor detection
14
0 0 0 0 Constant setting of magnetron
thermistor detection
15
1 5 Interval time setting of magnetron
thermistor detection
20
0 0 0 0 Switch level setting of magnetron
thermistor detection
OTHER CHECKING AND CLEARING PROCE-
DURE FOR R-23AT
1) To check the contents of defrost.
PAD ORDER
(Door close)
CHECK
"NUMBER"
DEFROST
CHECK
#1: No key entry signal.
2) How to clear all counter(user and service) and total
cooking time and used time of filter.
PAD ORDER
(Door close)
SET
SET
"NUMBER" •
DOUBLE
"NUMBER" • DOUBLE
CHECK
"NUMBER" • DOUBLE
VOLUME
"NUMBER" • DOUBLE
SET
30
Contents
"
" : Flicker /
: 0.1 sec BUZZER
DISPLAY
PHONE
CHECK
1
0.20 DEF
CHECK
(A)
DEF
CHECK
1
20
POWER
(+ - B)
50%
2
0.13 DEF
CHECK
(A)
DEF
CHECK
2
30
POWER
(+ - B)
30%
DEF
CHECK
3
5
POWER
20%
(Repeat)
DISPLAY
PHONE