Weld Process Board Pc4 Diagnostic Led's; Diagnostic Led's On Process Board Pc4 - Miller Axcess 300 Owner's Manual

Hide thumbs Also See for Axcess 300:
Table of Contents

Advertisement

8-2. Weld Process Board PC4 Diagnostic LED's

1

8-3. Diagnostic LED's On Process Board PC4

LED
Status
1
On
Off
2
On
Off
3,4
On
Off
OM-216 967 Page 30
Indicates −25 volts dc is present on process board PC4
Indicates −25 volts dc is not present on process board PC4
Indicates +25 volts dc is present on process board PC4
Indicates +25 volts dc is not present on process board PC4
See Network Status Table in Section 8-4
See Network Status Table in Section 8-4
1
Weld Process Board PC4
Diagnostic LED's are visible inside unit,
located on PC4 mounted on the top tray.
Refer to Section 8-3 for information on
diagnostic LED's.
Reinstall cover after checking diagnostic
LED's.
LED1
LED2
LED3
LED4
Diagnosis
216 956-A / Ref. 803 670-A

Advertisement

Table of Contents
loading

Table of Contents