Setting the Card ID

Setting the Logical Address Switch

Chapter 2
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
The Card ID Jumpers indicate which terminal assembly is used. Since the
HP E1343-66201 and E1345-66201 assembly is used with a variety of
terminal modules, the ID jumpers may be changed. To reduce setup time and
avoid configuration errors, check the jumpers to make sure they match the
terminal module used.
When the relay multiplexers are shipped from the factory, the Card ID
Jumpers are set according to the terminal module (E1343/44/45/47/55/56)
shipped with them. The system is able to identify the multiplexer with or
without the terminal module attached.
Note
If the jumper setting does not match the terminal module attached, the
system will identify the card based on the jumper setting.
The address switch (LADDR) factory setting is 112. You may have changed
the setting during module installation. Valid address values are from 0 to
255. Refer to the HP 75000 Series B System Installation and Getting Started
Guide or the HP E1406 Command Module Manual for addressing
information. Otherwise, to change the setting, refer to the
Figure 2-3. Locate and Set the Logical Address Switch