ELECTRICAL CONNECTION

WARNING
-
The manufacturer declines all liability for injury to persons or animals and for damage to property resulting from failure to observe the regulations
provided in this chapter.
-
The power cable must be long enough to allow the hob to be removed from the worktop.
-
Make sure the voltage specified on the dataplate located on the bottom of the appliance is the same as that of the home.
Connect to terminal Block
For the electrical connection a power cord ( 5x2.5 mm ) is present in the supply. To connect to the terminal block, follow the instuction below:
Remove shunts from terminal block
Before power cord connection remove the two shunts as per picture
Secure the power cable with the cable clamp.
Remove the terminal cover (A) by unscrewing the screw and insert the cover into the hinge (B) of the terminal.
Close the cover (C) and screw on the terminal with the screw removed.
Connect to wall side
For 220-240V 1N use the cord paired as supplied.
-
Disconnect the appliance from the power supply.
-
Installation must be carried out by qualified personnel who know the current safety and
installation regulations.
L1=R BLACK        L2=S BROWN    
N1=N BLUE         N2=N GREY with blue film
Connecting to the terminal block
For 380-415V 3N or 380-415V 2N, separate with the scissors the wires as showed in the image below and
connect them.
EN16
=E YELLOW-GREEN