7. Carefully remove the spring-loaded
cap, and then pull out the brush (4)
and replace. (Fig. ii)
8. Repeat step 6 and 7 for the other
side of motor.
9. Place the new brush into the
opening of motor, making sure the
ears on the metal end of the
assembly go in the same hole the
carbon part fits into. Do not
overtighten the plastic cap.
10. Carefully set the saw in a upright
position on a clean level surface.
11. Replace the blade guard, blade,
rip fence, miter gauge and stand
assembly to the table saw.
NOTE: To reinstall the same brushes,
first make sure the brushes go back in
the same sides they came out.
This will avoid a break-in period that
reduces motor performance and
increases wear.
Fig. ii
2
4
3
49