SAFETY PRECAUTIONS Please read the Safety Precautions before installing or using the BC300 External Shunt and CommLink. Be sure to observe all precautions without fail. Failure to observe these instructions properly may result in personal damage or personal injury which, depending on the circumstances, may be serious and cause loss of life.
CAN communication bus for reception by a BatteryPlus35 or J35. The CAN communication bus also provides operating power for the CommLink. The CAN communication bus can also be used to connect to a BMPRO Battery Monitor, such as the BMPRO Odyssey or Trek3.
DESCRIPTION OF PARTS BC300 EXTERNAL SHUNT 1. NEGATIVE BATTERY CONNECTION 2. NEW NEGATIVE TERMINAL CONNECTION Connects to the load. NOTE: This terminal has flat sides. 3. ‘+’ POSITIVE FLYING LEAD AND TEMPERATURE SENSOR 4. LED STATUS INDICATOR...
COMMLINK CAN BUS SOCKETS Used to connect to other BMPRO devices, such as the BatteryPlus35 or J35, or BMPRO Battery Monitors such as the BMPRO Odyssey or Trek3. RECESSED STATUS INDICATOR RECESSED PAIR BUTTON Battery Battery Nodes Monitors Management Systems...
INSTALLING THE BC300 AND COMMLINK MOUNTING THE BC300 The BC300 External Shunt has two mounting terminals. Using these terminals, the BC300 External Shunt is wired in series with the negative terminal of the battery being monitored and the negative battery loads. The ‘+’...
Once these connections are made the BatteryPlus35 or J35, the BC300 External Shunt and CommLink will be powered and will enter pairing mode. For information on pairing the BC300 External Shunt with the Commlink, refer to Pairing the BC300 with the CommLink. Connecting the BC300 to a Parallel Battery Installation When connecting the BC300 to a parallel battery installation, the earth strap that links the batteries together must remain on the battery terminals, and must be...
Reconnect the BC300 External Shunt’s positive flying lead from the battery positive terminal. Repeat the pairing process. If you have multiple pairing failures, try installing the CommLink closer to the BC300 External Shunt, or identify possible interference sources. This may require a longer data cable to locate the CommLink closer to the BC300 External Shunt.
SPECIFICATIONS BATTERY MONITORING SPECIFICATIONS Voltage Range 8V to 16V Voltage Resolution <20mV Current Resolution <200mA Current Range 240A continuous Overload Protection (100ms without damage) ± 800A Temperature Range (Battery Terminal) -20 to 70°C Temperature Resolution 3°C Capacity Range 7 to 800Ah BC300 EXTERNAL GENERAL SPECIFICATIONS COMMLINK...
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected, • Consult the dealer or an experienced radio/TV technician for help. Warning: Any changes or modifications not expressly approved by BMPRO could void the user’s authority to operate this equipment.
WARRANTY TERMS AND CONDITIONS (AUSTRALIA) Registering your BMPRO product is an important step to ensure that you receive all the benefits you are entitled to. Please visit teambmpro.com to complete the online registration form for your new product today. BMPRO goods come with guarantees that cannot be excluded under Australian Consumer Law.
• BMPRO may seek reimbursement of any costs incurred when a product is found to be in proper working order or damaged as a result of any of the warranty exclusions listed above.