Maintenance overview

Maintenance interval
After the first
25 operating hours
Every 8 operating hours /
daily
Every 150 operating hours /
every 6 months
Every 150 operating hours /
every year
The regulations of the engine manufacturer must be complied with in addition to the above main-
tenance overview!
Work must be carried out using regulation tools, and the operating and maintenance manual must
be complied with for all work.
All maintenance work: Select collection vessels large enough to prevent oil from spilling onto the
ground. Dispose of waste oil in an environmentally friendly manner (regulation on waste oils).
Dispose of oils, greases, cloths soaked in oil, and replaced parts with oil on them in an environ-
mentally friendly manner.
If lubricating oils and fuel come into contact with skin, they can cause skin cancer. Upon contact
with the skin, clean affected skin with suitable cleaning agent without delay.
If accessible during maintenance, check the condition and stability of all screws.
16
Maintenance point
Engine
Machine cpl.
Air filter
Engine
Vibrator
Engine
Maintenance activity
– Change the engine oil
– Check valve play,
adjust if necessary
– Re-tighten all accessible
threaded connections
– Clean air filter insert,
check for damage,
replace if necessary
– Change the engine oil
– Change oil
– Adjust valve play
– Clean spark plug
Adjust electrode gap
CFR 90