ELECTRICAL REQUIREMENTS

WARNING
This Boiling Water Unit contains electronic equipment and insulation tests must
only be conducted between neutral and earth or between active and earth.
• 230 – 240 Volts AC, 50 Hz, Single Phase
• 7.5 Amps on 3 litre
• 10 Amps on 5, 7.5,10 & 15 litre models
• 15 Amps on 25 litre model
• 20 Amps on 40 litre model
A flexible cord is supplied on all 3, 5, 7.5, 10 and 15 litre models. Do not loosen the
cord grip or pull excess cord into the Boiling Water Unit. If the supply cord of this unit
is damaged, it must be replaced by the manufacturer or a qualified service person.
The 25 and 40 litre models must be installed with fixed wiring. A means of
disconnection from all active (phase) conductors of the power supply must be
incorporated during installation in accordance with the wiring rules.