End Charging Process - AEG WM 18 Instructions For Use Manual

Shop charging device
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 17
Voltage "V"
28.7
27.2
26.5
21- 24.5(v)
24
21
5.4 - 6A
24 V
Once the battery has reached a voltage between 28.2 V and 28.7 V the battery is
fully charged. As soon as the voltage drops to 26.7 V maintenance charging will
start.

End charging process

1. Unplug from the AC outlet.
2. Disconnect the charging clamp (black) from the vehicle's body, in exceptions
from the negative battery terminal (marked N or -).
3. Disconnect the positive charging clamp (red) from the positive battery terminal
(marked P or +).
26.7 - 27.4(v)
25.5- 26.4(v)
4.3 - 5.2A
3.2 - 4.1A
Shop charging device WM18 - 24 V
Charging current "A"
27.5 - 28.7(v)
26.7(v)
maintenance charge
1.8 - 2.6A
<1A
GB
27
Time "t"