Finish training
1 Unplug the battery pulser from the power outlet
2 Disconnect the black (-) terminal connection cable from the negative battery terminal
3 Disconnect the red (+) terminal connection cable from the positive battery terminal
CHARGING PHASES
Step 1: Diagnosis
The battery pulser will check the battery condition
Step 2: Full load charging (Bulk-Mode)
The battery pulser will charge the battery up to 85% capacity
Step 3: Absorption charge
The battery pulser will charge the battery up to 85-100% capacity
Step 4: Automatic On/Off monitor
The battery pulser monitors the battery voltage Once the battery drops to below 128 V,
the battery pulser will start diagnostics again This maintains the battery's highest possi-
ble charging level
SAFETY FUNCTIONS
The charger features the following safety features to prevent damage to the charger and
the battery or the vehicle:
Short circuit (defective battery)
incorrect connection (connected with reversed polarity)
overcharging