Mitsubishi Electric GOT1000 GT11 Series Startup Manual page 4

Graphic operation terminal

Advertisement

PC
Example Connection Diagram:
The following is an example of an FX-to-GOT-to-PC connection, where
the blue lines indicate data communication and the red line indicates power
from the FX3U 24V DC service power supply.
FX3U-
422-BD
FX3U-16MR-ES/UL
GT01-C100R4-8P
Firmware Updates:
To make sure the GT11 Series GOT
is able to use the latest functions and
features, it is the responsibility of the user to
check and update the firmware (Standard
monitor OS) of the GOT.
Launch the latest copy of GT Designer2 and
start a new project for the GOT model "GT11**-Q(320x240)" with the
Note: This document is for reference only. For detailed settings and safety information refer to the respective product manual.
USB
GT1155-QTBD
(Front)
GT1155-QTBD
(Back)
"MELSEC-FX" Controller Type. Select
"Yes" to set the Communication Setting
and make sure the Standard I/F-1 or
Standard I/F-2 CH No. is set to 1,
depending on RS-422 or RS-232C
connection, before selecting "OK". The
"Screen Property" window that pops up for
making a new screen can be either
canceled or accepted for the following
steps.
Go to the "Communication" menu and
select "To/From GOT" to bring up the
4
GOT
PC
USB