Download Print this page
Hatco Flav-R-Shield ES90 Installation Manual
Hatco Flav-R-Shield ES90 Installation Manual

Hatco Flav-R-Shield ES90 Installation Manual

Self- service sneeze guards

Advertisement

Quick Links

Flav-R-Shield™
Self- Service Sneeze Guards
Model ES90
Model ES90 Self-Service Sneeze Guards are available in ten widths
ranging from 36"–144" (914–3658 mm), with a common height of
22-5/8" (575 mm) and a common depth of 16-1/4" (413 mm).
For additional information regarding Model ES90 sneeze guards,
scan the QR Code below:
https://www.hatcocorp.com/en/equipment/sneeze-guard-equipment/
self-service/flav-r-shield-self-service-sneeze-guard-es90
Important Safety Information
To avoid serious injury and damage to equipment or property, read
the following safety information before installing this equipment.
Do not attempt to assemble and install sneeze guards alone.
Installation of sneeze guards requires two or more people,
dependent upon unit.
Always wear proper protective eye wear when handling glass
sneeze guards.
Never spray cleaners directly onto sneeze guard surfaces. Spray
cleaner into non-abrasive cloth, and then wipe down surfaces.
Use non-abrasive cleaners and cloths only. Abrasive cleaners
and cloths could scratch finish of unit, marring its appearance
and making it susceptible to soil accumulation. Use of abrasive
materials will void warranty.
Assembly and Installation
1. Unpack all components. Verify that the appropriate number of
the items below are present.
• Face Panel, 3/8" Tempered Glass
• End Panel, 3/8" Tempered Glass
• Top Shelf, 3/8" Tempered Glass
• Post Assembly, 1" Stainless Steel
• Rear Horizontal Support, 1" Stainless Steel
Center Post Assembly, 1" Stainless Steel (multiple bay only)
• Orbit Bracket
• Hardware Packet (includes hex wrenches for set screws)
2. Remove the Mounting Flanges from each Post Assembly.
a. Slide the Flange Cover up and off of the flange.
b. Using the included hex wrench, loosen the set screw on the
flange.
c. Slide the flange off of the Post Assembly.
IMPORTANT NOTE
Sneeze guards that consist of multiple bays require careful
measurement before installation of the Mounting Flanges.
3. Install the Mounting Flanges to the mounting surface.
a. Refer to the "Model ES90 Standard Sizes" chart and
illustration below to determine the location of the flanges. For
multiple bay installations, refer to "Width per Bay" column in
the chart.
b. Position the flanges in the appropriate locations, and mark
the screw hole locations. IMPORTANT! Measure carefully,
and make sure the flanges remain square to each other as
well as the installation location.
c. Pre-drill the screw holes in the mounting surface.
d. Install the flanges using the appropriate, #8 countersunk-
style fasteners for the mounting surface.
© 2022 Hatco Corporation
INSTALLATION GUIDE
Model ES90 Standard Sizes
Total Width (A)
(post center to
Item Number
center)
ES90-036
(914 mm)
ES90-048
(1219 mm)
ES90-060
(1524 mm)
ES90-072
(1829 mm)
ES90-084
(2134 mm)
ES90-096
(2438 mm)
108"
ES90-108
(2743 mm)
120"
ES90-120
(3048 mm)
132"
ES90-132
(3353 mm)
144"
ES90-144
(3658 mm)
ES90-36 (1 Bay)
Rear
Horizontal
Support
A
ES90-60 (2 Bay)
30"
NOTE: 18" End Panels meet NSF requirements.
4. Install the Rear Horizontal Support(s) between each Post
Assembly.
5. Ensure the the Orbit brackets are installed on the front of each
Post Assembly before installing the Post Assemblies into the
Mounting Flanges.
6. Insert each Post Assembly into its corresponding Mounting
Flange. Make sure the posts are fully seated in the flanges.
7. Tighten the set screw on each Mounting Flange securely.
8. Slide each Flange Cover down onto its corresponding flange.
1
P/N 07.14.006.00-0922 [ES90_IG]
Number
Width per Bay
of
(post center to
Bays
center)
36"
1
(914 mm)
48"
1
(1219 mm)
60"
2
(762 mm)
72"
2
(914 mm)
84"
2
(1067 mm)
96"
2
(1219 mm)
2
(1372 mm)
3
(1016 mm)
3
(1118 mm)
3
(1219 mm)
22-5/8"
16-1/4"
Center Post
Assembly
30"
A
36"
48"
30"
36"
42"
48"
54"
40"
44"
48"
continued...

Advertisement

loading

Summary of Contents for Hatco Flav-R-Shield ES90

  • Page 1 7. Tighten the set screw on each Mounting Flange securely. d. Install the flanges using the appropriate, #8 countersunk- 8. Slide each Flange Cover down onto its corresponding flange. style fasteners for the mounting surface. continued... © 2022 Hatco Corporation...
  • Page 2 Use coin Filler Cap here. Assembly www.hatcosneezeguards.com installed. Filler Cap Cover Top side of glass Underside HATCO CORPORATION panel. of glass P.O. Box 340500 panel. Milwaukee, WI 53234-0500 U.S.A. 414-671-6350 support@hatcocorp.com Filler Cap www.hatcocorp.com Cover © 2022 Hatco Corporation...

This manual is also suitable for:

Flav-r-shield es90-036Flav-r-shield es90-048Flav-r-shield es90-060Flav-r-shield es90-072Flav-r-shield es90-084Flav-r-shield es90-096 ... Show all