3.3.3 Error register

Field/Bit Description
Bit
7
6
ICRCE UNC
• ICRCE (Interface CRC Error) indicates that a CRC error occurred on
the data bus during a Synchronous DMA transfer. The correct re-
sponse for this error is to retry the complete command. ABRT (bit 2)
is also set to ensure compatibility with drivers designed for previous
versions of the Synchronous DMA Transfer Protocol Specification.
• ABRT (Aborted Command) indicates that the requested command
was aborted because the command code or a command parameter
was invalid, or some other error occurred. The device may complete
some portion of the command before setting ABRT and terminating
the command. If the command was a data-transfer command, the data
transfer is determinate. This bit is also set when an Interface CRC
Error (bit 7) occurs. This ensures compatibility with drivers designed
for previous versions of the Synchronous DMA Protocol Specification.
5
4
3
2
MC
IDNF
MCR ABRT TKONF AMNF
37