Medalist 2520 Product Manual, Rev. A
on half-sine shock pulses of 11 msec, as specified in MIL-STD-202F).
Shocks are not to be repeated more than two times per second.
1.14.2 Nonoperating shock
The nonoperating shock level that the drive can experience without
incurring physical damage or degradation in performance when sub-
sequently put into operation is 200 Gs (based on repetitive half-sine
shock pulses of 2 msec duration, as defined in MIL-STD-202F).
1.14.3 Operating vibration
The maximum vibration levels that the drive can experience while
meeting the performance standards specified in this document are:
5–22 Hz
22–350 Hz
1.14.4 Nonoperating vibration
The maximum nonoperating vibration that the drive can experience
without incurring physical damage or degradation in performance when
put into operation are:
22–350 Hz
350–500 Hz
0.012-inch displacement (peak to peak)
0.5 Gs acceleration (zero to peak)
5.0 Gs acceleration (zero to peak)
3.0 Gs acceleration (zero to peak)
13