Error Register - Seagate Medalist Pro Family Product Manual

Medalist pro family ata interface drives
Hide thumbs Also See for Medalist Pro Family:
Table of Contents

Advertisement

36
Medalist Pro 6450/6451 Product Manual, Rev. B
During the entire burst, –CS0, –CS1, and –IOCS16 are in the high
negated state. DA2, DA1 and DA0 are driven low.
The drive begins driving and stops tristating IORDY when –DMACK
is first asserted and SyncDMA is enabled. The drive must continue to
drive IORDY until –DMACK is de-asserted and then tristates IORDY
within (Tiordyz) nanoseconds.
A device that supports a particular mode timing must support all slower
modes

3.3.3 Error Register

Field/Bit Description
7
6
Bit
ICRCE UNC
ICRCE (Interface CRC Error) indicates that a CRC error occurred on
the data bus during a Synchronous DMA transfer. The correct re-
sponse for this error is to retry the complete command. ABRT (bit 2)
is also set to ensure compatibility with drivers designed for previous
versions of the Synchronous DMA Transfer Protocol Specification.
ABRT (Aborted Command) indicates that the requested command
was aborted because the command code or a command parameter
was invalid, or some other error occurred. The device may complete
some portion of the command before setting ABRT and terminating
the command. If the command was a data-transfer command, the data
transfer is determinate. This bit is also set when an Interface CRC
Error (bit 7) occurs. This ensures compatibility with drivers designed
for previous versions of the Synchronous DMA Protocol Specification.
5
4
3
2
MC
IDNF
MCR ABRT TKONF AMNF
1
0