Table 1
Table 2
overview
This User Manual as well as those offered separately on other components,
etc., are intended to assure that the WaterGard system serves you properly
for the maximum possible time. Since product warrantability may well depend
upon your actions, please read this User Manual thoroughly prior to operation.
This User Manual provides information regarding general installation and op-
eration. Any deviation from, change or modification to, the User Manual, the
original design conditions or the original intended use of the equipment may
result in improper installation and/or operation.
Any such deviation, change or modification shall be the responsibility of
the party or parties making such deviation, change or modification. SPX
Cooling Tech expressly disclaims all liability for any such deviation, change
or modification. The equipment shall be warranted in accordance with the
applicable SPX Cooling Tech Certification of Limited Warranty.

Technical Information

Model
Nominal Rejection
Rated Product Flow – gpm*
Recovery
Size
Quantity
Type
Inlet Pressure Range - psig
* Product flow rate varies with temperature. All models are rated at 60°F (15.5°C).
Permeate flow for individual elements may vary -20 +25%.
Model
Minimum 50°F
WG002
2
WG004
4
WG007
6
WG009
8
Specifications
WG002
WG004
WG007
Performance
91%
2.2
4.4
7.3
85-90%
Membranes
4" x 40"
4" x 40"
4" x 40"
2
4
6
Low fouling spiral-wound composite
30-80
Maximum and Minimum Flow
Flow - gpm
Minimum 60°F
Maximum 50°F
2.2
2.75
4.4
5
7.3
8
9.0
10.5
WG009
9.0
4" x 40"
18
Reject
Reject
Minimum
Maximum
gpm
gpm
.22
.61
.44
1.21
.73
2.01
.9
2.48
3