Operating Status Messages - SPX MARLEY WaterGard WG002 User Manual

Table of Contents

Advertisement

Figure 5
Figure 6
operation

Operating Status Messages

The main operating status of the unit is shown on the top line of the display:
POWER OFF: The unit is off.
RO RUNNING: WaterGard unit is operating.
RO STARTING: WaterGard unit is starting up.
TANK FULL: The unit is shut down due to a collection basin full condition.
PRETREAT: The Unit is shut down due to a pretreat lockout condition.
PRESS FAULT: The unit is shut down to a low-pressure fault condition.
The secondary operating status is shown on the second line of the display.
SYSTEM FLUSHING: WaterGard flush is active. The number is the minutes
remaining in the flush cycle.
PUMP DELAY: The unit is in the WaterGard start delay. The number is the
seconds remaining before the WaterGard pump starts.
Temperature—The current permeate water temperature is shown on the second
line. If equipped, the line will alternate with feed temperature.
Conductivity—The permeate conductivity is shown on the second line. If
equipped, the third line will show feed conductivity. These values will alternate
with water temperature on second line and percent rejection on third line.
WaterGard Runtime—The current operating hours are shown on the bottom
line. See Figure 5.