Operating instructions
Solenoid interlock
Emergency exit
(Fitting and actuation only from within the hazardous area)
To activate the emergency exit of the T version in case of an emergency,
the orange lever must be turned to the stop in direction marked by
the arrow. The emergency exit function of the TD and TU versions is
activated by pressing the red pushbutton.
In this position, the safety guard can be opened. The blocking condition
is cancelled by turning the lever in opposite direction or by pulling back
the pushbutton. In unlocked position, the safety guard is protected
against unintentional closing.
Lateral emergency exit
(ordering suffix -T)
The user must evaluate and design the safety chain in
accordance with the relevant standards and the required
safety level.
The entire concept of the control system, in which the safety
component is integrated, must be validated to the relevant
standards.

2.4 Technical data

Standards:
IEC 60947-5-1, ISO 14119, BG-GS-ET-19
Enclosure:
Actuator and locking bolt:
Contact material:
Coding level according to ISO 14119:
Protection class:
Contact type:
Change-over contact with double break type Zb,
with galvanically separated contact bridges
Switching system:
Positive break travel:
Positive break force:
Connection:
Cable type:
Cable section:
Cable entry:
Holding force F
:
max
Latching force:
Actuating speed:
Actuating frequency:
Mechanical life:
Ambient temperature:
Electrical data:
Utilisation category:
Rated operating current/voltage I
- CC, SK, ST 4 pole:
- ST 8 pole:
Rated impulse withstand voltage U
- CC, SK, ST 4 pole:
- ST 8 pole:
Rated insulation voltage U
:
i
- CC, SK, ST 4 pole:
- ST 8 pole:
Emergency exit on the
cover side or on the rear side
(ordering suffix -TD/-TU)
glass-fibre reinforced thermo-
plastic, self-extinguishing
stainless steel 1.4301
A acc. IEC 60947-5-1 slow action,
NC contact with positive break
10 N for each NC contact fitted
screw terminals or cage
clamps or connector
min. 0.25 mm², max. 1.5 mm²
(including conductor ferrules)
4 x M16 x 1.5
30 N for ordering suffix R
max. 2 m/s
max. 1000 operations/h
> 1 million operations
–25 °C ... +60 °C
AC-15, DC-13
/U
:
e
e
4 A / 230 VAC
2.5 A / 24 VDC
2 A / 24 VDC
:
imp
Thermal test current I
- CC, SK, ST 4 pole:
- ST 8 pole:
Rated control voltage U
Magnet:
Power consumption:
Max. fuse rating:
Required rated short-circuit current:
Use Type 4X (Indoor Use) and 12 connector ittings.
Tightening torque rating: 4.4 lb in.
2.5 Safety classification
Standards:
Envisaged structure:
- Basically:
- With 2-channel usage and
fault exclusion mechanism*:
B
(NC contact):
10d
B
(NO contact) at 10% ohmic contact load:
10d
Service life:
* If a fault exclusion to the 1-channel mechanics is authorised.
B
10d
MTTF
d
0,1 x n
op
(Determined values can vary depending on the application-specific
parameters h
, d
op
op
If multiple safety components are wired in series, the Performance
Level to ISO 13849-1 will be reduced due to the restricted error
detection under certain circumstances.

3. Mounting

Silver
high

3.1 General mounting instructions

IP67
On delivery, the actuator is in inserted condition. For
power-to-unlock components, the actuator must be released
by means of the manual release. If the triangular key is
turned 180°, the locking bolt is pulled into the unlocking
10 mm
position. The normal locking function is only restored after
the triangular key has been returned to its original position.
Three mounting holes are provided for fixing the enclosure. The
flexible
solenoid interlock is double insulated. The use of an earth wire is not
authorised. The solenoid interlock must not be used as an end stop.
Any mounting position. The mounting position however must be chosen so
that the ingress of dirt and soiling in the used opening is avoided. Unused
2000 N
actuator openings must be sealed with slot sealing plugs.
The safety component and the actuator must be
permanently fitted to the safety guards and protected
against displacement by suitable measures (tamperproof
screws, gluing, drilling, pinning).
Please observe the remarks of the standards ISO 12100,
EN 953 and ISO 14119.
4 kV
0.8 kV
250 V
60 V
EN
:
the
:
s
applicable up to Cat. 1 / PL c
applicable up to Cat. 3 / PL d
with suitable logic unit
d
x
h
x
3600
op
op
n
op
t
cycle
and t
as well as the load.)
cycle
AZM 161 I
6 A
2 A
24 VAC / DC;
110 / 230 VAC
100% ED
max. 10 W
6 A gG D-fuse
1000 A
ISO 13849-1
2,000,000
1,000,000
20 years
s/h
3

Advertisement