Safety-monitoring module

Advertisement

Operating instructions
Safety-monitoring module

1.7 Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from
defective mounting or failure to comply with this operating instructions
manual. The manufacturer shall accept no liability for damages resulting
from the use of unauthorised spare parts or accessories.
For safety reasons, invasive work on the device as well as arbitrary re-
pairs, conversions and modifications to the device are strictly forbidden;
the manufacturer shall accept no liability for damages resulting from
such invasive work, arbitrary repairs, conversions and/or modifications
to the device.

2 Product description

2.1 Ordering code

This operating instructions manual applies to the following types:
SRB 031LC/0.6 sec
Factory-set drop-out delay: 0.6 seconds
Only if the information described in this operating instructions
manual are realised correctly, the safety function and therefore
the compliance with the Machinery Directive is maintained.

2.2 Special versions

For special versions, which are not listed in the order code below 2.1,
these specifications apply accordingly, provided that they correspond to
the standard version.

2.3 Destination and use

The safety-monitoring modules for integration in safety circuits are
designed for fitting in control cabinets. They are used for the safe
evaluation of the signals of positive break position switches or magnetic
safety sensors for safety functions on sliding, hinged and removable
safety guards as well as emergency stop control devices and AOPD's.
The safety function is defined as the delayed opening of the enabling
circuits 17-18, 27-28 and 37-38 when the inputs S11-S12 and/or
S11-S22 are opened. The safety relevant current paths with the output
contacts 17-18, 27-28 and 37-38 meet the following requirements under
observation of a B
value assessment (also refer to "Requirements to
10d
DIN EN ISO 13849-1"):
– control category 3 – PL d to DIN EN ISO 13849-1
– corresponds to SIL 2 to DIN EN 61508-2
– corresponds to SILCL 3 to DIN EN 62061
(corresponds to control category 4 to DIN EN 954-1)
To determine the Performance Level (PL) of the entire safety function
(e.g. sensor, logic, actuator) to DIN EN ISO 13849-1, an analysis of all
relevant components is required.

2.4 Technical data

General data:
Standards:
Climate resistance:
Fixing:
Terminal designations:
Material of the enclosure:
Material of the contacts:
Weight:
2
IEC/EN 60204-1, EN 60947-5-1;
EN ISO 13849-1, IEC/EN 61508
EN 60068-2-78
Snaps onto standard DIN rails
to DIN EN 60715
EN 60947-1
glass-fibre reinforced thermoplastic,
ventilated
AgSnO, self-cleaning, positive drive
230 g
Start conditions
Feedback circuit (Y/N):
Drop-out delay:
Pull-in delay:
Mechanical data:
Connection type:
Cable section:
Connecting cable:
Tightening torque
for the terminals:
With removable terminals (Y/N): No
Mechanical life:
Electrical life:
Resistance to shock:
Resistance to vibrations
to EN 60068-2-6:
Ambient conditions:
Ambient temperature:
Storage and transport
temperature:
Protection class:
Air clearances and creepage
distances to IEC/EN 60664-1:
EMC rating:
Electrical data:
Contact resistance in new state: max. 100 mΩ
Power consumption:
Rated operating voltage U
:
e
Max. fuse rating of the
operating voltage:
Monitored inputs:
Cross-wire detection (Y/N):
Wire breakage detection (Y/N): Yes
Earth leakage detection (Y/N):
Number of NO contacts:
Number of NC contacts:
Cable lengths:
Conduction resistance:
Outputs:
Number of safety contacts:
Number of auxiliary contacts:
Number of signalling outputs:
Switching capacity of the
safety contacts:
Switching capacity of the
auxiliary contacts:
Fuse rating of the
safety contacts:
Recommended fuse for
the auxiliary contacts:
Utilisation category to
EN 60947-5-1:
Dimensions (H/W/D):
The data specified in this manual are applicable when the component
is operated with rated operating voltage U
EN
SRB 031LC/0,6 sec
Automatic or start button
Yes
600 ms ± 30%
≤ 30 ms
Screw terminals
min. 2 mm
2
/ max. 2 mm
2
rigid or flexible
0.6 Nm
10 million operations
Derating curve available on request
10 g / 11 ms
10 ... 55 Hz, amplitude 0.35 mm
–25°C ... +45°C
–40°C ... +85°C
Enclosure: IP 40,
Terminals: IP 20,
Wiring compartment: IP 54
4 kV/2 (basic insulation)
to EMC Directive
max. 1.7 W / 1.9 VA
24 VDC –15%/+20%,
residual ripple max. 10%
internal F1: T 1.25 A
No
Yes
0
2
1,500 m with 1.5 mm²
2,500 m with 2.5 mm²
max. 40 Ω
3
1
0
17-18; 27-28; 37-38:
max. 250 V, 6 A ohmic (inductive in
case of appropriate protective wiring)
45-46: 24 VDC / 2 A
6.3 A slow blow
2 A slow blow
AC-15 / DC-13: EN 60947-5-1
100 mm x 22.5 mm x 121 mm
±0%.
e