TYPE OF PROBLEM
Fluid pressure
Mechanical
Electrical
NOTE: Thaw sprayer if water or water–based paint has frozen in it, due to exposure to low temperatures, by placing in a warm
area. Do not try to start sprayer until completely thawed or damage to motor and/or start board may occur. If paint hardened
(dried) in sprayer, the pump packings (page 22) and/or pressure transducer (page 28) must be replaced.
14
308752

Troubleshooting

WARNING
Basic Problem Solving
WHAT TO CHECK
If check is OK, go to next check
1. Check pressure control knob setting. The pump
won't develop much pressure if it is at minimum
setting (fully counterclockwise).
2. Check for a clogged spray tip or fluid filter, if
used. See page 9.
1. Check for frozen or hardened paint in pump
(20). Using a screwdriver, carefully try to rotate
fan at back of motor by hand. See page 19.
2. Check pump connecting rod pin (17). It must be
completely pushed into connecting rod (15),
and retaining spring (18) must be firmly in con-
necting rod groove. See Fig. 19, page 22.
3. Check for motor damage. Remove drive hous-
ing assembly (11). See page 25. Try to rotate
motor fan by hand.
1. Check electrical supply with volt meter. Meter
should read 90–110 VAC.
2. Check extension cord for visible damage. Use
a volt meter or test lamp at extension cord out-
let to check.
3. Check sprayer power supply cord (57) for vis-
ible damage such as broken insulation or wires.
4. Check motor brushes for the following:
a. Loose terminal screws.
b. Broken or misaligned brush springs.
c. Brushes binding in holders.
d. Broken leads.
e. Worn brushes.
NOTE: The brushes do not wear at same rate
on both sides of motor. Check both brushes.
WHAT TO DO
When check is not OK, refer to this column
1. Slowly increase pressure setting to see if
motor starts.
2. If tip is still clogged, relieve pressure; re-
fer to separate gun or tip instruction man-
ual for tip cleaning. Clean or replace filter
element. See manual 308429.
1. Thaw. Plug in sprayer and turn on.
Slowly increase pressure setting to see if
motor starts. If it doesn't, see NOTE, be-
low.
2. Push pin into place and secure with
spring retainer.
3. Replace motor (4) if fan won't turn. See
page 23.
1. Reset building circuit breaker; replace
building fuse. Try another outlet.
2. Replace extension cord.
3. Replace power supply cord.
See page 24.
4. Refer to page 20.
a. Tighten.
b. Replace broken spring and/or align
spring with brush
c. Clean brush holders. Remove carbon
with small cleaning brush. Align brush
leads with slot in brush holder to as-
sure free vertical brush movement.
d. Replace brushes
e. Replace brushes if less than 12.5 mm
(0.5 in.) long.