Fisher FSAI-CP-90BE3 Service Manual page 92

Split wall-mounted type
Table of Contents

Advertisement

Service Manual
Step
Rotate the electric box assy. Twist off the screws
c
Rotate the electric box assy. Twist offthe
that are locking the wire clip and loosen the
screwsthat are locking the wire clip and
power cord. Remove the wiring terminal of
loosen the power cord. Remove the wiring
power cord. Lift up the main board and take it off.
terminal of power cord. Lift up the main
board and take it off.
Instruction:Some wiring terminal of this
products is with lock catch and other
devices.The pulling method is as below:
① Remove the soft sheath for some
terminals at first, hold the circlip and then
pull out the terminals,
② Pull out the holder for some terminals at
first(holder is not available for some wiring
terminal).hold the connector and then pull
the terminal.
9.Remove evaporator assy
Remove 3 screws fixing evaporator assy.
a
b
At the back of the unit, remove the screw
fixing connection pipe clamp and then
remove the connection pipe clamp.
First remove the left side of evaporator from
c
First remove the left side of evaporator from
the groove on the rear case assy. Then
remove the right side from the clasp on the
the groove on the rear case assy. Then
rear case assy.
remove the right side from the clasp on the
rear case assy.
Installation and Maintenance
Procedure
Power
co
rd
Circlip
Soft sheath
Groove
Screws
Wire clip
Rear case assy
Holder
Connector
Clasp
89

Advertisement

Table of Contents
loading

Table of Contents