Fisher FSAI-CP-90BE3 Service Manual page 51

Split wall-mounted type
Table of Contents

Advertisement

Display Method of Indoor Unit
Indicator Display (during
blinking, ON 0.5s and OFF
Dual-8
Malfunction
No.
0.5s)
Code
Name
operation
Display
Indicator
Compressor
intermediate
26
P3
frequence in
test state
Overcurrent
protection of
27
phase
P5
current for
compressor
Charging
malfunction
28
PU
of capacitor
Malfunction
of module
29
P7
temperature
sensor circuit
Module high
30
temperature
P8
protection
Overload
31
protection for
H3
compressor
IPM
32
H5
protection
Malfunction
of zero-cross
33
U8
detection
circuit
48
Cool
Heating
Indicator
Indicator
During cooling and drying
operation, compressor will stop
while indoor fan will operate;
During heating operation, the
complete unit will stop operation.
During cooling and drying
operation, compressor will stop
while indoor fan will operate;
During heating operation, the
complete unit will stop
During cooling and drying
operation, compressor will stop
while indoor fan will operate;
During heating operation, the
complete unit will stop
During cooling operation,
compressor will stop while indoor fan will
operate; During heating operation, the
complete unit will stop
During cooling and drying
operation, compressor will stop
while indoor fan will operate;
During heating operation, the
complete unit will stop operation.
During cooling and drying
operation, compressor will stop
while indoor fan will operate;
During heating operation, the
complete unit will stop operation.
The complete unit stops
A/C status
Showing during middle cooling or middle
heating test
Refer to the malfunction analysis (IPM
protection, loss of synchronism protection
and overcurrent protection of phase current
for compressor.
Refer to the part three—charging malfunction
analysis of capacitor
Replace outdoor control panel AP1
After the complete unit is de-energized for
20mins, check whether the thermal grease on
IPM Module of outdoor control panel AP1 is
sufficient and whether the radiator is inserted
tightly. If its no use, please replace control
panel AP1.
1. Wiring terminal oVC-CoMP is loosened. In
normal state, the resistance for this terminal
should
be less than 1ohm.
2.Refer to the malfunction analysis (
discharge protection, overload)
Refer to the malfunction analysis (IPM
protection, loss of synchronism protection
and overcurrent protection of phase current
for compressor.
1.Power supply is abnormal;
2.Detection circuit of indoor control mainboard
is abnormal.
Service Manual
Possible Causes
Installation and Maintenance