1
About this document
1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualiied personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
Product description
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 Safety classiication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
3
Mounting
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4
Electrical connection
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .3
5
Operating principle and settings
5.1 Operating principle after the operating voltage is switched on . . . . 3
6
Set-up and maintenance
6.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
6.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
7
Disassembly and disposal
7.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
7.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
8
Appendix
8.1 Wiring examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
8.2 Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Encontrará el manual de
ES
instrucciones actual en su
idioma oicial de la UE en
nuestra página de Internet
www.schmersal.net.
Il manuale d'istruzioni
IT
aggiornato nella vostra lingua
(lingua uficiale UE) è scarica-
bile in Internet all'indirizzo
www.schmersal.net.
1 About this document
1.1 Function
This operating instructions manual provides all the information you need
for the mounting, set-up and commissioning for the safe operation and
disassembly of the safety-monitoring module. The operating instructions
must be available in a legible condition and a complete version in the
vicinity of the device.
1.2 Target group: authorised qualiied personnel
All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operat-
ing instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards to
be complied with as well as other technical speciications for the selection,
mounting and integration of the components.
1.3 Explanation of the symbols used
Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.
1.4 Appropriate use
The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the proper functionality of the entire machinery or plant.
The safety-monitoring module must be exclusively used in accordance
with the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".
1.5 General safety instructions
The user must observe the safety instructions in this operating instructions
manual, the country-speciic installation standards as well as all prevailing
safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is provided
without liability und is subject to technical modiications.
The entire concept of the control system, in which the safety
component is integrated, must be validated to EN ISO 13849-2.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.
EN
AES 6112
AES 7112
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the AES 6112 and is the answer not in the manual?

Questions and answers

Summary of Contents for schmersal AES 6112

  • Page 1 3.2 Dimensions ......... . .3 Further technical information can be found in the Schmersal...
  • Page 2 AES 7112.1: 180 g Design AES 7112.2: 180 g The AES 6112 and AES 7112 have a triple redundant structure for moni- AES 7112.3: 135 g toring guard doors. A irst fault can lead to a failure of one of the three...
  • Page 3 S.. 3.2 Dimensions AES 6112 Device dimensions (H/W/D): AES 6112: 48 x 96 x 58 mm Guard door monitoring by means of a magnetic safety sensor (BNS) AES 7112: 105 x 96 x 58 mm 4 Electrical connection 4.1 General information for electrical connection...
  • Page 4 Authorised signature Heinz Schmersal Managing Director Note The currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net. K. A. Schmersal GmbH Industrielle Sicherheitsschaltsysteme Möddinghofe 30, D - 42279 Wuppertal Postfach 24 02 63, D - 42232 Wuppertal...