Requirements On The Wall Outlet - Bellfires Smart Bell 55 Preparation Manual

Hide thumbs Also See for Smart Bell 55:
Table of Contents

Advertisement

Requirements
(*) Items:
A ventilation opening that services an occupied room, a toilet or a bathroom.
A combustibion air supply, if the supply flows through an occupied room.
A window that can be opened that services an occupied room, a toilet or a bathroom.
4.3.2

Requirements on the wall outlet

Make sure that the outlet is installed at least 0.5 meter from:
The corner of a building
the edge of the roof
The roof overhang and rain gutter
Balconies etc. unless the exhaust construction extends to at least the face of the
protruding section
If the outlet is installed horizontally in less than 0.5 m and vertically in less than 2 m from
a public area, install an effective protector. Make sure that the mesh size of the guard
does not affect the operation of the appliance.
If the height of the outlet is less than 3 meter from the floor, the distance between the
outlet and a garden or a terrace must be at least 2 meter.
On a wall where the item services a living space other
Under a balcony, walkway, etc. if the outlet extends to the
8
L L ocation of any of the items(*)
At the same roof as the outlet
At a different roof as the outlet
At a lower positioned wall than the outlet
At a higher sloping surface than the outlet
Note:
All the minimum distances are guidelines. Consult your national and local
directives for the exact minimum distances.
Location of any of the items(*)
than that of the owner of the fireplace.
On a wall (**)
within 1 meter of the roof overhang
Under a balcony, walkway, etc.
front
A facing wall less than 2 meters from the outlet.
Minimum distance between the items
and the roof outlet
3 m
1 m
1 m
3 m
Minimum distance between the items
and the wall outlet
Do not install the wall outlet under an
item.
Below the item: 2 m
Above the item: 0.75 m
Left or right of the outlet: 0.75 m
2 m
2 meter from the underside of the bal-
cony or walkway
2 m
Apply the minimum distance for items
on a wall.