Technical data
8.4 Other properties
Note
The following applies to IE Switches X-300:
The number of IE Switches X-300 connected in a line influences the frame delay time. When a
frame passes through the switch, this is delayed by the Store&Forward function of the
IE Switch X-300 by the following values:
• at 64 bytes frame length: Delay of approx. 10 microseconds (at 100 Mbps)
• at 1500 bytes frame length: Delay of approx. 130 microseconds
(at 100 Mbps)
This means, the more IE Switches X-300 a frame runs through, the higher the frame delay.
PRP compatibility
Device variant
X308-2M
X308-2M TS
* Information about the firmware version (V) as of which PRP is supported.
Note
For a device to be used in PRP networks, it must be able to process a frame length of at least 1528
bytes (Jumbo Frames). This value is the maximum frame length including VLAN tag of
1522 bytes plus the length of the PRP trailer of 6 bytes. The following table shows the version
as of which the devices are PRP-compatible.
58
As of version *
V3.7.0
Compact Operating Instructions, 05/2023, A5E02630801-14
SCALANCE X-300M