Spin Test; Motor Brush Replacement - Graco 232903 Repair Manual

Airless paint sprayers
Hide thumbs Also See for 232903:
Table of Contents

Advertisement

Setup
Electric Shock Hazard; page 4.
To check armature, motor winding and brush electrical
continuity:
1.
Relieve pressure; page 4.
2. Remove drive housing; page 17.
3. Fig. 3. Remove pressure control cover (39). Dis-
connect motor leads (F) and (G).
4. Fig. 4. Remove motor shroud (74).
Armature Short Circuit Test
Quickly turn motor fan by hand. If no electrical shorts,
motor coasts two or three revolutions before complete
stop. If motor does not spin freely, armature is
shorted. Replace motor; page 18.

Motor Brush Replacement

Motor Brush Removal
Replace brushes worn to less than 1/2 in. Check both
sides. Brush Repair Kit 243215.
1. Read General Repair Information; page 4.
2.
Relieve pressure; page 4.
3. Fig. 4. Remove four screws (18) and motor
shroud (74).
4. Pry off brush cap (A).
5. Fig. 5. Remove screw (C) and discard brush (B).
(Continued on page 11)
10
309063

Spin Test

Armature, Brushes, and Motor Wiring Open
Circuit Test (Continuity)
1. Connect red and black motor leads together with
test lead. Turn motor fan by hand at about two
revolutions per second.
2. If uneven or no resistance, check for: broken brush
springs, brush leads, motor leads; loose brush
terminal screws, motor lead terminals; worn
brushes. Repair as needed; page 10.
3. If still uneven or no resistance, replace motor;
page 18.
39
Fig. 3
74
Fig. 4
F
G
18
A
9578A
TI0053

Advertisement

Table of Contents
loading

This manual is also suitable for:

232900190es232906

Table of Contents