JOINON EASY UNITÀ DI RICARICA VEICOLI ELETTRICI JOINON EASY - JOINON EASY ELECTRIC VEHICLE RECHARGING UNIT - UNIDAD DE CARGA PARA VEHÍCULOS ELÉCTRICOS JOINON EASY - JOINON EASY ELEKTROMOS JÁRMŰTÖLTŐ EGYSÉG Manuale di utilizzo ed installazione - User and installation manual - Manual de uso e instalación - Használati és telepítési útmutató...
JOINON EASY electric vehicle recharging unit CONTENTS INFORMATION ABOUT THIS MANUAL 1.1. Field of application 1.2. Intended users 1.3. Symbols REGULATORY ASPECTS 2.1. Fulfilment of regulations 2.2. Degree of protection 2.3. Degree of pollution 2.4. Current socket-outlets SAFETY 3.1. Safety conditions 3.2.
Page 3
STATUS INDICATORS CHARGING PROCESS 10.1. FREE 10.2. RFID 10.3. CLOUD FAULTS AND TROUBLESHOOTING UPDATING THE FIRMWARE MODIFYING THE OPERATING PARAMETERS OF THE RECHARGING STATION DISCONNECTING FROM THE MAINS SUPPLY PREVENTIVE MAINTENANCE 15.1. DIFFERENTIAL CURRENT DEVICES...
JOINON EASY electric vehicle recharging unit INFORMATION ABOUT THIS MANUAL This manual describes the JOINON EASY electrical vehicle recharging station and provides the necessary infor- mation for correct delivery, installation, start-up, maintenance and operation. FIELD OF APPLICATION This manual applies for the following charging stations: - GW68122 –...
REGULATORY ASPECTS FULFILMENT OF REGULATIONS CE marking CE marking is essential for marketing the products in question within the European Union and the European Eco- nomic Area. The charging stations have CE marking as they comply with the following directives: •...
Gewiss declines all liability for any damage caused by inappropriate use of the charging stations. Any operation carried out on these charging stations that involves a change to the original electrical settings must be authorised by Gewiss beforehand. All such proposals must be examined and approved by Gewiss.
Potential hazards for the device In order to protect the device, observe the following warnings. Before reconnecting the voltage supply after any duly authorised operation, make sure the device is ready to start working. Then, connect it following the instructions in the manual. Do not touch the boards or the electronic components;...
Keep the device packaged until installation. 4.2. DEVICE IDENTIFICATION The serial number of the device identifies it in an unequivocal manner. In any communication with Gewiss, refer- ence must be made to this number. The device serial number is indicated on the label inside the door above the one-way switches.
• Avoid striking or dropping the mechanical stations as this could deteriorate the mechanical properties. • Avoid, as far as possible, the vibrations that could cause subsequent abnormal operation. If a fault is discovered, contact Gewiss immediately. Packaging disposal The packaging can be sent to an authorised non-hazardous waste agent.
JOINON EASY electric vehicle recharging unit Remember that it could occasionally produce a small amount of condensation as a result of temperature changes. Therefore, in addition to the protection it has, the charging stations must be monitored when they are used in areas where it is probable that not all the previously indicated conditions will be satisfied.
DEVICE INSTALLATION AND CONNECTION Before proceeding with device installation, remove the packaging, paying particular attention to not damage the casing. Make sure there is no condensation inside the packaging. Otherwise, install the device only when it is completely dry. All the installation operations must be carried out in compliance with the directive in force. All operations that involve moving large weights must be done by two people.
Page 12
JOINON EASY electric vehicle recharging unit • Fastening with plastic brackets GW 44 621 (not provided) • Fastening with pole support brackets GW 46 552 (not provided) 2. After installing the product on the wall, fix the cable support in place (only for versions with a mobile connector). It can be installed in the lower part of the device or next to one of the sides.
7.2.2. CONNECTING THE DEVICE POWER SUPPLY Protection devices The circuit breaker and residual current protection devices required by the low voltage electrical system standard must be installed upstream of the charging station. If there are no indications concerning the residual current protection to be used, each station must be protected by residual current circuit breakers installed upstream - either: •...
Page 14
JOINON EASY electric vehicle recharging unit Connection procedure 1. Open the casing as shown in the figure. 2. Drill the back-mounting box using a multi-diameter drill (not supplied) at the top or the bottom as required. GW 52 401 3. Connect the power supply cable to the input terminal block, then tighten the cable using the cable gland. L1 L2 L3 N PE 4.
OPERATION Depending on the model, there are different ways of accessing the recharging service. The various operating modes are explained below. 8.1. FREE AUTOSTART mode indicates that the charging station is always available, without any need for client identification via RFID cards or an app. The car is simply connected to the station and the recharging session begins automat- ically.
JOINON EASY electric vehicle recharging unit CHARGING PROCESS The steps needed to carry out a recharging session are indicated below (they may vary according to the operating mode). 10.1. FREE The charging station is always accessible and ready to begin a recharging session as soon as a car is connected. It's fitted with a selector for choosing the recharging power.
Close the charging station and reconnect the power supply to launch the updating procedure Once the command has been executed, the station will return to standby Contact GEWISS SAT customer service for the UID codes of your RFID cards; you will be asked to give the number on the cards.
JOINON EASY electric vehicle recharging unit To delete an RFID card from the local list: Action to be carried out RGB LED status Swipe the MASTER key across the RFID scanner to enable From fixed green to flashing white the storage phase Swipe the MASTER key across the RFID scanner again to From flashing white enable the deletion phase...
In the case of products connected to the JOINON platform, or if the maintenance package has been purchased, call the FreePhone number 800 123 325. In all other cases where technical support is required, call GEWISS SAT customer service. UPDATING THE FIRMWARE Charging stations not designed for remote connection to the cloud platform can be updated using the microSD card in the relative slot of the electronic board.
Insert the microSD card in the specific slot on your PC, to open the folder Paste the update file in the main folder of the microSD card NOTE: contact GEWISS SAT customer service for the most recent file (which will also be available on the GEWISS website)
DISCONNECTING FROM THE MAINS SUPPLY This section describes the procedure for disconnecting the mains network from the device. If you want to work inside the device (qualified personnel only), first operate the circuit breaker located in the enclosure that protects the electron- ic board and then the protection located upstream of the power supply line.