IS 12-14-16-19 GENERATORS WIRING DIAGRAM Fig.19 - 7 -...
Page 8
IS 12-14-16-19 GENERATORS INDEX Pictures ........................... 2 Wiring diagram ........................7 GENERAL INFORMATION ....................16 Purpose and field of application of the manual ..............16 Symbols .......................... 16 Prescriptions for safety during installation and setup ..........17 INSTALLATION ......................17 Characteristics of the installation space ................
MANUAL WILL RESULT IN FORFEITURE OF THE GUARANTEE ON THE PRODUCT 1.1 Purpose and field of application of the manual Thank you for choosing a mase product. This manual has been drawn up by the manufacturer with the purpose of providing essential information and instructions for proper installation in conditions of safety and constitutes an integral part of the generator equipment.
2 - System with baffle near electric equipment (including lamps) or parts MASE recommends the direct infeed system (ref.1 fig. 3) of the electrical system. since this system prevents water under pressure enter-...
Page 11
IS 12-14-16-19 GENERATORS 4.2.2 Typical installation with generator below the 4.4.1 Typical installation of generator with gas/ water line (Fig.5) water separating exhaust type “GENSEP” above the water line (Fig.8) Sea exhaust Silencer Sea exhaust - gas Muffler Sea exhaust - water Water filter Gas/water separating muffler type GENSEP Main system tap...
IS 12-14-16-19 GENERATORS Components Drainage system The flue gas/water drainage system of the generator The sea water intake system must must be separate from that of the main motors be separate from the one for the engines propelling the boat. The length of the tube from the highest point of the drain duct to the muffler should 1 - Direct sea intake 1/2"...
IS 12-14-16-19 GENERATORS 6 ELECTRICAL CONNECTIONS 1 Parallel connection: in this configuration there is the following output: Battery connection - 115V-50Hz or 120V-60Hz between the points 11 and To start off the unit an independent battery of 12V is 4 by connecting the alternator outputs 33-11 and 2-4 needed, capacity 80 Ah.
Page 14
IS 12-14-16-19 GENERATORS 6.4. Generator - Mains switching A switch should be placed on the line to switch the user appliances from the generator to an external power line. The switch should be dimensioned according to the size of the loads: a general diagram is shown in fig.18. 7 HANDLING For handling and lifting of the generator only use the lifting hook located on the engine.