Operating instructions
1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Failure to observe the instructions may cause damage to the device and result in fire and
other hazards.
Danger of electric shock. Always disconnect before carrying out work on the devise or
load. At the same time, take into account all circuit breakers that supply dangerous
voltage to the device or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage.
The load is not electrically isolated from the mains even when the device is switched off.
Do not connect any electronic lamps, e.g. switchable or dimmable compact fluorescent
lamps or LED lamps. Device can be damaged.
Fire hazard. For operation with inductive transformers, each transformer must be fused
on the primary side in accordance with the manufacturer's instructions. Only safety
transformers according to EN 61558-2-6 may be used.
The radio communication takes place via a non-exclusively available transmission path,
and is therefore not suitable for safety-related applications, such as emergency stop and
emergency call.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
(1) Dimmer
(2) LED
(3) Programming button
3 Function
System information
By statute, the reception characteristics and the antenna cannot be changed.
The device may be operated in all EU and EFTA countries.
The declaration of conformity can be viewed on our website.
The range of a radio system from the transmitter to the receiver depends on various
circumstances.
32532123
J:0082532123
Figure 1
1/8
17.12.2010

Advertisement

loading
Need help?

Need help?

Do you have a question about the FUSD 1253 and is the answer not in the manual?

Questions and answers

Summary of Contents for Jung FUSD 1253

  • Page 1 Radio Management Radio universal in-line dimmer Radio universal in-line dimmer Art.-No.: FUSD 1253 Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause damage to the device and result in fire and other hazards.
  • Page 2 Radio Management Radio universal in-line dimmer The range of the system can be optimised by selecting the optimal installation location, taking into account the structural circumstances. Figure 2: Reduced range due to structural obstacles Example of penetration of various materials: Material Penetration Wood, plaster, plasterboard...
  • Page 3: Operation

    Radio Management Radio universal in-line dimmer Dimmable inductive inductive Phase cut-on transformers with halogen lamps i Flickering of the connected lamps due to undershoot of the specified minimum load or through centralised pulses from the power stations. These are not device faults. i Brief flickering upon load detection of ohmic loads.
  • Page 4 Radio Management Radio universal in-line dimmer 5 Information for electrically skilled persons 5.1 Fitting and electrical connection DANGER! Electrical shock when live parts are touched. Electrical shocks can be fatal. Always disconnect the device from the socket outlet before carrying out work on the load.
  • Page 5 Radio Management Radio universal in-line dimmer Figure 4: Connection diagram for corded dimmer with extension 2-wire Figure 5: Connection diagram for corded dimmer with installation button i Lit installation buttons must have a separate N terminal. Connect the dimmer with screw terminals according to the connection diagram: i Recommended cable for effective strain relief: H05VV-F 3G 0.75 Switch on mains voltage The dimmer automatically sets the dimming principle suitable for the load.
  • Page 6 Radio Management Radio universal in-line dimmer DANGER! Electrical shock when live parts are touched. Electrical shocks can be fatal. Before working on the device, cover up live parts in the working environment. Teaching a radio transmitter i If all memory slots are occupied, a radio transmitter which has already been taught must first be deleted.
  • Page 7: Troubleshooting

    Radio Management Radio universal in-line dimmer 6 Appendix 6.1 Technical data Rated voltage AC 230 V ~ Mains frequency 50 / 60 Hz Ambient temperature 0 ... +55 °C Connected load at 35 °C i Power specifications including transformer power dissipation. i Operate inductive transformers with at least 85% nominal load.
  • Page 8: Warranty

    We provide a warranty as provided for by law. Please send the unit postage-free with a description of the defect to our central customer service office: ALBRECHT JUNG GMBH & CO. KG Service Center Kupferstr. 17-19 D-44532 Lünen Service-Line: +49 (0) 23 55 .