NOTICE
Improper installation of the load cell in the compact mounting unit
An improper installation of the load cell in the compact mounting unit can destroy the load cell
and the compact mounting unit.
● Check that the load cell and compact mounting unit are installed correctly, for example, by
● To prevent water from penetrating, lay cables through cable glands in the form of a vertical
5.2

Dismantling

For dismantling the load cells, the same safety rules apply as for installation.
1. Disconnect all the supply voltages and auxiliary voltages.
2. Secure the load carrier against falling.
3. Use appropriate hoisting gear and tools.
4. Take the load off the load cell.
5. Carefully remove the load cell without using force. Do not pull on the cable of the load cell.
6. If you intend to reinstall the load cell or send it for repair, do not cut the load cell cable.
7. Do not carry the load cell by the cable.
DB-S CA 2.3 ... 113 t
Operating Instructions, 10/2019, A5E46619167-AA
checking the mounting dimensions and oscillation distances. See the section Technical
data (Page 23).
downwards loop.
Installation
5.2 Dismantling