MTU 12V 4000 L64 Operating Instructions Manual page 104

Table of Contents

Advertisement

1.4520.640 – MIC5 ISE Secon Short Circuit Cyl 11
Yellow alarm. Initiated by MIC5.
Cause
Short circuit in secondary circuit
of cylinder 11 in ignition
sequence.
1.4520.641 – MIC5 ISE Secon Short Circuit Cyl 12
Yellow alarm. Initiated by MIC5.
Cause
Short circuit in secondary circuit
of cylinder 12 in ignition
sequence.
1.4520.642 – MIC5 ISE Secon Short Circuit Cyl 13
Yellow alarm. Initiated by MIC5.
Cause
Short circuit in secondary circuit
of cylinder 13 in ignition
sequence.
1.4520.643 – MIC5 ISE Secon Short Circuit Cyl 14
Yellow alarm. Initiated by MIC5.
Cause
Short circuit in secondary circuit
of cylinder 14 in ignition
sequence.
1.4520.644 – MIC5 ISE Secon Short Circuit Cyl 15
Yellow alarm. Initiated by MIC5.
Cause
Short circuit in secondary circuit
of cylinder 15 in ignition
sequence.
1.4520.645 – MIC5 ISE Secon Short Circuit Cyl 16
Yellow alarm. Initiated by MIC5.
Cause
Short circuit in secondary circuit
of cylinder 16 in ignition
sequence.
104 | Troubleshooting | MS15027/04E 2017-08
Corrective action
1. Check ignition lead, connector and igniter.
2. Check ignition coil.
Corrective action
1. Check ignition lead, connector and igniter.
2. Check ignition coil.
Corrective action
1. Check ignition lead, connector and igniter.
2. Check ignition coil.
Corrective action
1. Check ignition lead, connector and igniter.
2. Check ignition coil.
Corrective action
1. Check ignition lead, connector and igniter.
2. Check ignition coil.
Corrective action
1. Check ignition lead, connector and igniter.
2. Check ignition coil.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

16v 4000 l64

Table of Contents