Ferroli NAPOLI 600 Installation And Use Instruction page 47

Smart dry electric thermal emitter
Hide thumbs Also See for NAPOLI 600:
Table of Contents

Advertisement

Available languages

Available languages

N A P O L I
Note: If the window sill protrudes less than 20 mm, the gap above the emitter can be disregarded.
Legs Kit
If the Legs Kit is attached to the emitter, which can be purchased optionally, when being placed
it must be considered that it must be used on a horizontal and stable surface. In this case, the
emitter must not be used in the immediate surroundings of a bath, a shower or a swimming pool.
Once the thermal emitter is assembled with the Legs, keep textiles, curtains or any other flamma-
ble material a minimum distance of 1 m from the air outlet of the emitter.
3. ELECTRICAL CONNECTION
The thermal emitter must be connected to the power line (230 V ~ 50 Hz) through its plug. The
following warnings must also be taken into account:
- The device must not be located underneath an electrical outlet or switch.
- The power line should be protected with a high-sensitivity differential device.
4. MOUNTING
The thermal emitter must be held by its handles, as shown in the following image:
The thermal emitter must be fixed to the wall using the spacers, brackets, screws and wall plugs
supplied with the emitter, according to the instructions on the template printed on the box.
A73023143