System Setup Menu

The System Setup menu of the DN9848 enables global parameters: LCD contrast, RS-485 channel,
System and Panel Lockout status, the delay time units, power-on options on and the working memory
name. Note that if an RS-485 channel (other than Off) is selected, the front panel controls (other than the
HOME (SETUP) button)will not function.
If HOME (SETUP) is pressed and held down for at least one second while the first page of a menu is
being displayed, the system enters the context-sensitive Setup menu. The HOME (SETUP) button is
then used to step through the setup pages. When all the pages have been accessed, the next press of the
HOME (SETUP) button will return the user to the HOME page.
Pressing any other button while in Setup mode will exit the Setup menu and take the user to the HOME
page.
LCD Contrast
The display contrast is variable in 11 steps numbered 0 to 10 in so as to accommodate off-axis viewing
angles. The default setting is 5.
X: Display contrast.
Y: Not used.
Z: Not used.
RS-485
RS-485 can operate on any one of 256 possible channels at a fixed data rate of 38.4kHz (38400 baud).
The default condition is for the RS-485 channel to be set to off.
X: RS-485 channel.
Y: Not used.
Z: Not used.