Dewalt DW03050 - Laser Distance Measure Manual

Dewalt DW03050 - Laser Distance Measure Manual

Also See for DW03050:

Advertisement

Dewalt DW03050 - Laser Distance Measure Manual

Instrument Set-up

Introduction

warning The safety instructions and the user manual should be read through carefully before the product is used for the first time.

The person responsible for the product must ensure that all users understand these directions and adhere to them.

The symbols used have the following meanings:


Indicates a potentially hazardous situation or an unintended use which, if not avoided, will result in death or serious injury.


Indicates a potentially hazardous situation or an unintended use which, if not avoided, may result in minor injury and/or appreciable material, financial and environmental damage.

information Important paragraphs which must be adhered to in practice as they enable the product to be used in a technically correct and efficient manner.

Overview

Overview

Display

Display

Insert batteries

information To ensure a reliable use, do not use zinc-carbon batteries. Change batteries when battery symbol is flashing.

Operations

Switching ON/OFF

Clear


Undo last action.

Message Codes

If the info icon appears with a number, observe the instructions in section "Message Codes".

Example:

Adjusting measuring reference

Adjusting measuring reference

Distance unit setting

Measuring Functions

Measuring single distance

Measuring single distance

information Target surfaces: Measuring errors can occur when measuring to colourless liquids, glass, styrofoam or semi-permeable surfaces or when aiming at high gloss surfaces. Against dark surfaces the measuring time increases.

Permament measuring

Permament measuring

Add / Subtract

Add / Subtract

information The result is shown in the main line and the measured value above. This process can be repeated as required. The same process can be used for adding or subtracting areas or volumes.

Area

Area

information The result is shown in the main line and the measured value above.

Volume

Volume

Pythagoras (2-point)

Pythagoras (2-point)

information The result is shown in the main line and the measured distance above. Pressing the measuring key for 2 sec in the function activates automatically Minimum or Maximum measurement.

Pythagoras (3-point)

Pythagoras (3-point)

Memory (5 last results)

Memory (5 last results)

Technical Data

Distance measurement
Typical Measuring Tolerance* ± 1.5 mm / 0.06 in **
Range at Target Plate 50 m / 164 ft
Typical Range* 40 m / 132 ft
Range at unfavourable condition*** 35 m / 115 ft
Smallest unit displayed 1 mm / 1/16 in
Ø laser point at distances 6 / 30 mm (10 / 50 m)
General
Laser class 2
Laser type 635 nm, < 1 mW
Beam divergence 0.16 x 0.6 mrad
Impulse duration 0.2 x 10-9s - 0.8 x 10-9s
Protection class IP54 (dust- and splash water protected)
Autom. laser switch off after 90 s
Autom. power switch-off after 180 s
Battery durability (2 x AAA) up to 3000 measurements
Dimension (H x D x W) 120.5 x 55 x 33.7 mm
4.7 x 2.2 x 1.3 in
Weight (with batteries) 127 g / 4.48 oz
Temperature range:
  • Storage
-25 to 70°C
-13 to 158°F
  • Operation
0 to 40°C
32 to 104°F
Functions
Distance measuring yes
Permanent measuring yes
Addition/Subtraction yes
Area yes
Volume yes
Pythagoras 2-point, 3-point
Memory 5 results

* applies for 100% target reflectivity (white painted wall), low background illumination, 25 ºC

** Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.15 mm/m between 10 m to 30 m and to 0.2 mm/m for distances above 30 m

*** applies for 100% target reflectivity, background illumination of approximately 30'000 lux

Message Codes

If the message Error does not disappear after switching on the device repeatedly, contact the dealer.

If the message InFo appears with a number, press the Clear button and observe the following instructions:

No. Cause Correction
204 Calculation error Perform measurement again.
252 Temperature too high Let device cool down.
253 Temperature too low Warm device up.
255 Received signal too weak, measuring time too long Change target surface (e.g. white paper).
256 Received signal too high Change target surface (e.g. white paper).
257 Too much background light Shadow target area.
258 Measurement outside of measuring range Correct range.
260 Laser beam interrupted Repeat measurement.

Care

  • Clean the device with a damp, soft cloth.
  • Never immerse the device in water.
  • Never use aggressive cleaning agents or solvents.

Warranty

Europe:

  • 30 day no risk satisfaction guarantee
  • One year free service
  • One year full warranty

Detailed information are available on the internet at www.2helpU.com.

North America:

  • Three year limited warranty
  • One year free service
  • 90 day money back guarantee

Detailed information are available on the internet at www.dewalt.com.

Safety Instructions

The person responsible for the instrument must ensure that all users understand these directions and adhere to them.

Areas of responsibility

Responsibilities of the manufacturer of the original equipment:

Europe:
DEWALT
D-65510 Idstein, Germany
www.2helpU.com
www.dewalt.eu

North America:
DEWALT Industrial Tool Co.
Baltimore, MD21286, USA
For service call 1-800-4-DEWALT.
www.dewalt.com

The company above is responsible for supplying the product, including the User Manual in a completely safe condition.

The company above is not responsible for third party accessories.

Responsibilities of the person in charge of the instrument:

  • To understand the safety instructions on the product and the instructions in the User Manual.
  • To be familiar with local safety regulations relating to accident prevention.
  • Always prevent access to the product by unauthorised personnel.

Permitted use

  • Measuring distances
  • Tilt measurement

Prohibited use

  • Using the product without instruction
  • Using outside the stated limits
  • Deactivation of safety systems and removal of explanatory and hazard labels
  • Opening of the equipment by using tools (screwdrivers, etc.)
  • Carrying out modification or conversion of the product
  • Use of accessories from other manufacturers without express approval
  • Deliberate dazzling of third parties; also in the dark
  • Inadequate safeguards at the surveying site (e.g. when measuring on roads, construction sites, etc.)
  • Deliberate or irresponsible behaviour on scaffolding, when using ladders, when measuring near machines which are running or near parts of machines or installations which are unprotected
  • Aiming directly in the sun

Hazards in use


Watch out for erroneous measurements if the instrument is defective or if it has been dropped or has been misused or modified. Carry out periodic test measurements.
Particularly after the instrument has been subject to abnormal use, and before, during and after important measurements.


Never attempt to repair the product yourself. In case of damage, contact a local dealer.


Changes or modifications not expressly approved could void the user's authority to operate the equipment.

Limits of use

information Refer to section "Technical data".
The device is designed for use in areas permanently habitable by humans. Do not use the product in explosion hazardous areas or in aggressive environments.

Disposal



Flat batteries must not be disposed of with household waste. Care for the environment and take them to the collection points provided in accordance with national or local regulations.
The product must not be disposed with household waste.
Dispose of the product appropriately in accordance with the national regulations in force in your country.
Adhere to the national and country specific regulations.
Product specific treatment and waste management can be downloaded from our homepage.

Electromagnetic Compatibility (EMC)


The device conforms to the most stringent requirements of the relevant standards and regulations.
Yet, the possibility of causing interference in other devices cannot be totally excluded.

Laser classification

The device produces visible laser beams, which are emitted from the instrument: It is a Class 2 laser product in accordance with:

  • IEC60825-1: 2007 „Radiation safety of laser products"

Laser Class 2 products:

Do not stare into the laser beam or direct it towards other people unnecessarily. Eye protection is normally afforded by aversion responses including the blink reflex.


Looking directly into the beam with optical aids (e.g. binoculars, telescopes) can be hazardous.


Looking into the laser beam may be hazardous to the eyes.

Labelling


Attach the laser sticker (a) of your country language.

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Dewalt DW03050 - Laser Distance Measure Manual

Advertisement

Need Assistance?

Do you have a question about the DW03050 that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents