Symptom 2: Change into the fan mode during
cooling mode
In order to prevent the indoor evaporator frosting, the system
will change into fan mode automatically, restore to the cooling
mode after soon.
When the room temperature drops to the set temperature, the
compressor goes off and the indoor unit changes to fan mode;
when the temperature rises up, the compressor starts again. It
is same in the heating mode.
Symptom 3: White mist comes out of a unit
Symptom 3.1: Indoor unit
When humidity is high during cooling operation If the interior of
an
indoor
unit
is
extremely
distribution inside a room becomes uneven. It is necessary to
clean the interior of the indoor unit. Ask your dealer for details
on cleaning the unit. This operation requires a qualified service
erson
Symptom 3.2: Indoor unit, outdoor unit
When the system
is changed over to heating operation after
defrost
operation
Moisture
steam and is exhausted.
Sptom 4: Noise of air conditionerscooling
Symptom 4.1: Indoor unit
A continuous low "shah" sound is heard when the system is in
cooling operation or at a stop.
When the drain pump (optional accessories) is in operation,this
noise is heard.
A "pishi-pishi" squeaking sound is heard when the system stops
after heating operation.
Expansion
and
contraction
temperature change make this noise.
Symptom 4.2: Indoor unit, outdoor unit
A continuous low hissing sound is heard when the system is in
operation.
This is the sound of refrigerant gas flowing through both indoor
and outdoor units.
A hissing sound which is heard at the start or immediately after
stopping operation or defrost operation.
This is the noise of refrigerant caused by flow stop or flow
change.
Symptom 4.3: Outdoor unit
When the tone of operating noise changes.
This noise is caused by the change of frequency.
Symptom 5: Dust comes out of the unit
When the unit is used for the first time in a long time.
This is because dust has gotten into the unit.
Symptom 6: The units can give off odours
The unit can absorb the smell of rooms, furniture, cigarettes,
etc., and then emit it again.
Symptom 7: The outdoor unit fan does not spin.
During operation. The speed of the fan is controlled in order to
optimize product operation.
owner's manual
8
contaminated,
the
temperature
generated
by
defrost
becomes
of
plastic
parts
caused

8. TROUBLESHOOTING

8.1
Troubles and causes of air conditioner
If one of the following malfunctions occur, stop operation, shut
off the power, and contact with your dealer.
The operation lamp is flashing rapidly (5Hz) This lamp is still
flashing rapidly after turn off the power and turn on again.
(See in Table 8-1)
Remote controller receives malfunction or the button does not
work well.
A safety device such as a fuse, a breaker frequently actuates.
Obstacles and water enter the unit.
Water leaks from indoor unit.
Other malfunctions.
If
the
system
does
mentioned
cases
or
evident,
investigate
procedures. (See in Table 8-2)
8.2
Troubles and causes of remote controller
Before asking for serving or repairing, check the following
points.(See in Table 8-3)
by
not
properly
operate
except
the
above
mentioned
the
system
according
to
the
above
malfunctions