Emerson DIXELL XD70T Installing And Operating Instructions page 21

Table of Contents

Advertisement

Maximum time with compressor on
rEG
MCo
(0=disabled)
Compressor ON time in Energy Saving (0
rEG
tCE
= disabled)
Compressor selection during any defrost
rEG
Cdd
cycle
Regulation percentage=F(P1; P2)
rEG
rtr
(100=P1; 0=P2)
rEG
CCt
Maximum duration for Pull Down
Pull Down phase differential (SET+CCS
rEG
CCS
or SET+HES+CCS)
Threshold for automatic activation of Pull
rEG
oHt
Down in normal mode (SET+HY+oHt)
Threshold for automatic activation of Pull
rEG
oHE
Down in energy saving mode
(SET+HES+HYE+oHE)
rEG
Con
Compressor ON time with faulty probe
rEG
CoF
Compressor OFF time with faulty probe
Prb
P1C
Probe P1 selection
Prb
P2C
Probe P2 selection
Prb
P3C
Probe P3 selection
Prb
P4C
Probe P4 selection
Prb
ot
Probe P1 calibration
Prb
P2P
Probe P2 presence
Prb
oE
Probe P2 calibration
Prb
P3P
Probe P3 presence
Prb
o3
Probe P3 calibration
Prb
P4P
Probe P4 presence
Prb
o4
Probe P4 calibration
Temperature measurement unit: Celsius;
diS
CF
Fahrenheit
diS
rES
Temperature resolution: decimal, integer
diS
Lod
Local display visualization
Temperature display delay (resolution 10
diS
dLY
sec)
Probe visualization percentage=F(P1;P2)
diS
dtr
(ex: dtr=1 means
VALUE=0.01*P1+0.99*P2)
dEF
EdF
Defrost mode
dEF
tdF
Defrost type: electric heating, hot gas
dEF
dFP
Probe selection for defrost control
dEF
dSP
Probe selection for 2nd defrost control
dEF
dtE
End defrost temperature
dEF
dtS
End 2nd defrost temperature
Interval between two successive defrost
dEF
idF
cycles
dEF
MdF
Maximum length of defrost cycle
dEF
MdS
Maximum length of 2nd defrost cycle
dEF
dSd
Start defrost delay
Compressor off-cycle before starting any
dEF
StC
defrost
dEF
dFd
Displaying during defrost
1592020900 XD70T EN v1.0 2021.06.18.docx
0
Pr1
min
0
Pr1
min
2C
Pr1
100
Pr1
00:00
Pr1
hh:mm
0.0
Pr1
°C
10.0
Pr1
°C
10.0
Pr1
°C
5
Pr1
min
10
Pr1
min
ntC
Pr2
ntC
Pr2
ntC
Pr2
ntC
Pr2
0.0
Pr2
°C
yes
Pr2
0.0
Pr2
°C
no
Pr2
0.0
Pr2
°C
no
Pr2
0.0
Pr2
°C
°C
Pr2
dE
Pr2
P1
Pr2
00:00
Pr2
mm:ss
99
Pr2
in
Pr2
EL
Pr2
P2
Pr2
nP
Pr2
8.0
Pr2
°C
8.0
Pr2
°C
24
Pr2
hh:mm
30
Pr2
min
30
Pr2
min
0
Pr2
sec
0
Pr2
sec
dEF
Pr2
XD70T
[0 to 255 min]
0 to 255 min
CP1(0); CP2(1); 2C(2)
0 to 100
0 to 23h50min
[-12,0°C to 12,0°C]
[-21,6°F to 21,6°F]
[0,0°C to 25,0°C]
[0,0°F to 45,0°F]
[0,0°C to 25,0°C]
[0,0°F to 45,0°F]
0 to 255 min
0 to 255 min
ntC(0); Pt1(1); PtC(2)
ntC(0); Pt1(1); PtC(2)
ntC(0); Pt1(1); PtC(2)
ntC(0); Pt1(1); PtC(2); Cur(3)
[-12,0°C to 12,0°C]
[-21,6°F to 21,6°F]
n(0); Y(1)
[-12,0°C to 12,0°C]
[-21,6°F to 21,6°F]
n(0); Y(1)
[-12,0°C to 12,0°C]
[-21,6°F to 21,6°F]
n(0); Y(1)
[-12,0°C to 12,0°C]
[-21,6°F to 21,6°F]
°C(0); °F(1)
dE(0); in(1)
P1(0); P2(1); P3(2); P4(3);
SEt(4); dtr(5)
0.0 to 20min00sec
1 to 99
rtC(0); in(1); Sd(2)
EL(0); in(1)
nP(0); P1(1); P2(2); P3(3);
P4(4)
nP(0); P1(1); P2(2); P3(3);
P4(4)
[-50.0°C to 50.0°C]
[-58,0°F to 122,0°F]
[-50.0°C to 50.0°C]
[-58,0°F to 122,0°F]
0.0 to 24h00min
0 to 255 min
0 to 255 min
0 to 255 sec
0 to 255 sec
rt(0); it(1); SEt(2); dEF(3);
Coo(4)
21/47