Energy Saving Configuration Parameters - Es - Emerson DIXELL XD70T Installing And Operating Instructions

Table of Contents

Advertisement

Digital input 3 configuration: (nu; dor; dEF; AUS; ES; EAL; bAL; PAL; FAn; HdF; onF; LiG; CC;
EMt)
nu = not used
dor = door switch function
dEF = defrost activation
AUS = auxiliary output
ES = energy saving mode activation
EAL = external warning alarm
i3F
bAL = external lock alarm
PAL = external pressure alarm
FAn = evaporator fan control
HdF = holiday defrost
onF = ON/OFF status change
LiG = light output control
CC = change configuration (between C1 and C2)
EMt = Motion sensor X-MOD
Digital inputs 3 alarm delay (base time depends on par. Ibt): (0 to 255) delay between the
d3d
detection of an external event and the activation of the relative function.
Number of external pressure switch alarms before stopping the regulation: (0 to 15) after
nPS
reaching nPS events in the digital input alarm delay (par. Dxd), the regulation will be stopped and a
manual restart (ON/OFF, power OFF and power ON) will be required
Compressor and fan status after door opening: (no; FAn; CPr; F-C): no = normal;
odC
FAn = Fans OFF; CPr = Compressor OFF; F-C = Compressor and fans OFF.
Regulation restart after door alarm: (n; Y) n = no regulation if the door is open; Y = when the rrd
rrd
timer elapses, the regulation restarts even if a open door alarm is ON.
Light output activation from door input: (n; Y) the activation of a digital input set as ixF=dor
CLi
forces the light output ON.
Time with light output forced ON (0=function disabled): (0 to 255 min) interval with light output
LCi
forced ON.
Number of motion detections before activating light output (valid if ixF=EMt): (0 to 10)
n01
number of motion sensor detections before forcing the light output ON.
Time with light output forced ON after motion detection: (0 to 255 min) interval with light output
t01
forced ON from motion sensor.
Motion sensor stop reading interval after switching off the light output by button, serial
EMF
command or energy saving algorithm: (0 to 255 mim) valid only if ixF=EMt

5.1.10 Energy saving configuration parameters - ES

Energy saving algorithm: (nu; bAS) nu=disabled, the energy saving mode activation is by button,
ErA
real time clock or digital input; bAS=basic algorithm, the energy saving mode activation depends
on the the digital input.
Energy saving mode temperature differential: (-30.0 to 30.0°C; -54 to 54°F) sets the increasing
HES
value of the set point during the Energy Saving cycle.
Energy saving controls the lights (lights OFF when energy saving is active): (n; Y) lights off
LdE
when energy saving mode is active
Period to switch from normal mode to energy saving mode: (0.0 to 24h00min, res. 10 min) if
StE
the door stay closed for StE time, the energy saving mode will be activated. NOTE: this will require
a door switch to work.
Period to switch from energy saving mode to normal mode: (0.0 to 24h00min, res. 10 min)
EtS
maximum time for energy saving mode. NOTE: this will require a door switch to work.
Door opening time to switch from EtS to StE: (0 to 999 sec) the energy saving mode will be
dS
immediately deactivated as soon as the door stays open more than the dS time. NOTE: this will
require a door switch to work.
Number of motion detections before disabling energy saving mode (valid if ixF=EMt): (0 to
nES
255) number of motion sensor detections before disabling the energy saving mode.
1592020900 XD70T EN v1.0 2021.06.18.docx
XD70T
18/47